Etoori, Keerthana

Assessment of buildings with SSI and without SSI - Vol.96(9), Sep - Mumbai ACC LTD 2022 - 48-58p.

This study considers low (5-storey), medium (10-storey), and high-rise (20-storey) buildings on hard, medium, and soft soils according to IS code. These 9 buildings are designed for base shear obtained from IS: 1893-1 (2016)[11], fixed base and flexible base, respectively. This study shows that buildings designed according IS code are over designed when compared with flexible base. To check safety of these overdesigned buildings, linear dynamic analysis, and pushover analysis were performed. These analyses show that flexible base design is safer, and economical than IS code and fixed base design buildings.


Civil Engineering
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247