Lessons Learnt from the Collapse of Footbridge in Miami, USA (Record no. 11465)

000 -LEADER
fixed length control field a
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20200919151413.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 200919b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency AIKTC-KRRC
Transcribing agency AIKTC-KRRC
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 6372
Author Subramanian, N.
245 ## - TITLE STATEMENT
Title Lessons Learnt from the Collapse of Footbridge in Miami, USA
250 ## - EDITION STATEMENT
Volume, Issue number Vol.94(3), March
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Thane
Name of publisher, distributor, etc. ACC LTD
Year 2020
300 ## - PHYSICAL DESCRIPTION
Pagination 61-68p.
520 ## - SUMMARY, ETC.
Summary, etc. On March 15, 2018, a prestressed concrete truss footbridge in Miami, Florida, USA collapsed during construction. This bridge was designed as a ‘signature’ bridge with an unorthodox, non-redundant prestressed concrete truss bridge that was made to look like a cable-stayed bridge just for aesthetic appearance. The collapse of this footbridge caused several casualties and raised serious concerns about the design and construction of the bridge, in addition to the use of accelerated bridge construction (ABC). Recently the National Transportation Safety Board (NTSB), after conducting extensive investigations, released a report that attributed the collapse to flawed design, especially not providing enough shear transfer mechanism at the cold joint at the northern end of the bridge, and not considering the behaviour of the footbridge during all the construction stages. It also blamed all the involved agencies for their negligence of not proof checking the bridge design during all the construction stages. In addition it criticized the agencies for not considering the cracks (which were noticed near cold joints during the erection) as serious and life threatening even when the cracks were widening and subsequently lead to the collapse. As the failure of this bridge gives important lessons for bridge engineers, the features of the bridge and the reasons for its failure are described briefly.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 4621
Topical term or geographic name entry element Civil Engineering
773 0# - HOST ITEM ENTRY
Place, publisher, and date of publication Thane ACC Limited
Record control number icj
Title Indian Concrete Journal
856 ## - ELECTRONIC LOCATION AND ACCESS
URL https://www.icjonline.com/editionabstract_detail/032020
Link text Click here
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme
Koha item type Articles Abstract Database
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Permanent Location Current Location Shelving location Date acquired Barcode Date last seen Price effective from Koha item type
          School of Engineering & Technology (PG) School of Engineering & Technology (PG) Archieval Section 2020-09-19 2021133 2020-09-19 2020-09-19 Articles Abstract Database
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha