Some Aspects of Seismic Soil–Structure Interaction of Lifeline Structures (Record no. 15278)

000 -LEADER
fixed length control field a
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20210927114835.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 210927b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency AIKTC-KRRC
Transcribing agency AIKTC-KRRC
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 13268
Author Viladkar, M. N.
245 ## - TITLE STATEMENT
Title Some Aspects of Seismic Soil–Structure Interaction of Lifeline Structures
250 ## - EDITION STATEMENT
Volume, Issue number Vol.51(3), June
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Germany
Name of publisher, distributor, etc. Springer
Year 2021
300 ## - PHYSICAL DESCRIPTION
Pagination 467-481p.
520 ## - SUMMARY, ETC.
Summary, etc. Historically, underground structures were considered to be less vulnerable to earthquakes. However, some of the recent earthquakes have demonstrated that underground structures too can suffer severe damages, especially when these are located in the vicinity of causative faults. In case of a shallow underground tunnel excavated in an urban area, design and construction is demanding due to interaction between the tunnels and the overlying pre-existing structures. Selection of a realistic ground motion of an earthquake plays a crucial role in the seismic analysis and design of underground structures. In the absence of realistic earthquake data for the given area, it becomes essential to generate artificial or synthetic time history compatible with the largest earthquake expected in that area. Depending upon the situation, it may become necessary to consider three-dimensional aspects of the problem rather than depending on only a two-dimensional behavior. Strong ground shaking can as well cause loss of strength in saturated cohesion less soils resulting in liquefaction. Liquefaction can cause the ground surrounding the tunnels to shift, with potentially severe consequences. An attempt has been made in this paper to discuss various analysis and design considerations of underground lifeline structures and then look in to the aspects of stability of metro underground tunnels of Delhi city on basis of response spectra compatible time histories of 1999 Chamoli earthquake of Uttarakhand, actual three-dimensional analyses, and some liquefaction studies.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 4621
Topical term or geographic name entry element Civil Engineering
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 14367
Co-Author Singh, Manendra
773 0# - HOST ITEM ENTRY
Place, publisher, and date of publication Switzerland Springer
Title Indian geotechnical journal
International Standard Serial Number 0971-9555
856 ## - ELECTRONIC LOCATION AND ACCESS
URL https://link.springer.com/article/10.1007/s40098-021-00523-w
Link text Click here
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme
Koha item type Articles Abstract Database
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Permanent Location Current Location Shelving location Date acquired Barcode Date last seen Price effective from Koha item type
          School of Engineering & Technology (PG) School of Engineering & Technology (PG) Archieval Section 2021-09-27 2021-2022135 2021-09-27 2021-09-27 Articles Abstract Database
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha