Forensic Study of an Earth Retaining System Failure (Record no. 15286)

000 -LEADER
fixed length control field a
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20210928130120.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 210928b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency AIKTC-KRRC
Transcribing agency AIKTC-KRRC
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 14380
Author Joseph, Anil
245 ## - TITLE STATEMENT
Title Forensic Study of an Earth Retaining System Failure
250 ## - EDITION STATEMENT
Volume, Issue number Vol.51(3), June
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Germany
Name of publisher, distributor, etc. Springer
Year 2021
300 ## - PHYSICAL DESCRIPTION
Pagination 598-611p.
520 ## - SUMMARY, ETC.
Summary, etc. Forensic civil engineering can be considered as “The investigation of materials, products, structures or components that fail or do not operate or function as intended, causing personal injury or damage to property." This paper presents a case history of analysis and review of a touch pile system failure during deep excavation for a commercial building (3 basements, ground floor and 8 floors) near Metro Station Kaloor, Kerala. An excavation to a depth of 10 m from ground level was required to reach up to foundation level of the structure and to retain soil to facilitate the excavation; a retaining wall formed using touch pile system, where in multiple piles almost touching each other to support a change in elevation along with strutting was adopted. As the excavation was in progress, the shoring system collapsed at 9.30 pm on April 19, 2018. A technical expert committee was formed by District Disaster Management Authority, which comprised of authors to evaluate the reasons of failure. The immediate restoration steps adopted, various tests conducted to analyze the reasons for collapse, temporary measures adopted and precautions to be taken for future construction are presented. From the study, it was found that the strutting system was inadequate to take up the lateral thrust from the touch piles and soil at the dredge line has turned out to be very soft and has caused considerable loss of strength of the interface soil. Subsequent increase in unsupported length of pile is also a reason for the failure of retaining system.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 4621
Topical term or geographic name entry element Civil Engineering
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 14382
Co-Author Chandrakaran, S.
773 0# - HOST ITEM ENTRY
International Standard Serial Number 0971-9555
Title Indian geotechnical journal
Place, publisher, and date of publication Switzerland Springer
856 ## - ELECTRONIC LOCATION AND ACCESS
URL https://link.springer.com/article/10.1007/s40098-021-00532-9
Link text Click here
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme
Koha item type Articles Abstract Database
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Permanent Location Current Location Shelving location Date acquired Barcode Date last seen Price effective from Koha item type
          School of Engineering & Technology (PG) School of Engineering & Technology (PG) Archieval Section 2021-09-28 2021-2022143 2021-09-28 2021-09-28 Articles Abstract Database
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha