Parallel inverters control in standalone microgrid using different droop control methodologies and virtual oscillator control (Record no. 17514)

000 -LEADER
fixed length control field a
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20220913142826.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 220913b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency AIKTC-KRRC
Transcribing agency AIKTC-KRRC
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 17882
Author Vikash, Gurugubelli
245 ## - TITLE STATEMENT
Title Parallel inverters control in standalone microgrid using different droop control methodologies and virtual oscillator control
250 ## - EDITION STATEMENT
Volume, Issue number Vol.103(1), Feb
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. New York
Name of publisher, distributor, etc. Springer
Year 2022
300 ## - PHYSICAL DESCRIPTION
Pagination 163-171p.
520 ## - SUMMARY, ETC.
Summary, etc. Renewable Energy Sources (RES) have been found as viable alternatives for conventional power generation systems in recent times. The power electronic-based converters are the main medium of interface for connecting RES to the utility grid system. The prime focus of this paper is on inverter coordination methods to maintain system stability. The work is also attentive on the comparative examination of simple droop control, modified droop control, and Virtual Oscillator Control (VOC) methods for the control of parallel inverters operating in the standalone Microgrid (MG). The two different droop control methods are operated based on the active and reactive powers, which are phasor quantities, measured by sensed output voltage and current. Because of the phasor quantities, the dynamic response of the droop controller is insignificant. The VOC control mechanism works on instant current feedback signals, such that the dynamic performance of the system differs remarkably. The simulation results and the Opal-RT real-time digital simulation results corroborate that VOC gives a superior dynamic performance as compared to droop control.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 4642
Topical term or geographic name entry element Humanities and Applied Sciences
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 17883
Co-Author Ghosh, Arnab
773 0# - HOST ITEM ENTRY
Title Journal of the institution of engineers (India): Series B
International Standard Serial Number 2250-2106
856 ## - ELECTRONIC LOCATION AND ACCESS
URL https://link.springer.com/article/10.1007/s40031-021-00613-6
Link text Click here
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme
Koha item type Articles Abstract Database
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Permanent Location Current Location Shelving location Date acquired Barcode Date last seen Price effective from Koha item type
          School of Engineering & Technology School of Engineering & Technology Archieval Section 2022-09-13 2022-1582 2022-09-13 2022-09-13 Articles Abstract Database
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha