Dual wavelength based approach with partial least square regression for the prediction of glucose concentration (Record no. 17708)

000 -LEADER
fixed length control field a
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20221001160239.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 221001b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency AIKTC-KRRC
Transcribing agency AIKTC-KRRC
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 18194
Author Yadav, Deepshikha
245 ## - TITLE STATEMENT
Title Dual wavelength based approach with partial least square regression for the prediction of glucose concentration
250 ## - EDITION STATEMENT
Volume, Issue number Vol.60(8), Aug
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. New Delhi
Name of publisher, distributor, etc. CSIR
Year 2022
300 ## - PHYSICAL DESCRIPTION
Pagination 700-706p.
520 ## - SUMMARY, ETC.
Summary, etc. Diabetes mellitus is a group of metabolic disorder characterized by high blood sugar levels. Monitoring of blood glucose levels at regular intervals plays a crucial role in the management of diabetes. The non-invasive real-time monitoring of glucose using near-infrared (NIR), Raman, acoustic and bio-impedance techniques have an edge over available invasive techniques but suffers from low Signal to Noise ratio (S/N) and other interferences. In the present work, we have attempted to improve S/N for the efficient detection of feeble signals corresponding to the physiological glucose concentrations. Investigations were carried out in the NIR region particularly from 800-1400 nm for the identification of the unique absorption features of glucose using UV-Vis NIR spectrophotometer with different ranges of glucose concentrations including 5 g/dl- 45 g/dl, 1400 mg/dl -2500 mg/dl, 35 mg/dl-650 mg/dl . Savitzky Golay (SG) pre-processing filter was applied on the raw data for enhancing the S/N for better prediction of glucose concentrations. The absorption spectra of glucose revealed the presence of a peak at 960 nm. Therefore, considering the absorbance at 960 nm, provided an enhancement in the S/N ratio from 17 dB to 27 dB. Further, partial least square regression (PLSR), has been applied on SG filtered data for a better prediction of glucose concentration with a correlation coefficient ( R2) value of 0.99 and root mean square error of prediction (RMSE) of 2.29 mg/dl. Further, based on the NIR spectral data, we have developed a measurement technique using two LED sources of 950 nm and 860 nm, and a wide detector (700 - 1100 nm) which converts obtained optical signal into voltage. It has been observed that by considering dual wavelength detection points the prediction of glucose concentration is improved. Furthermore, with increase in the test glucose concentrations, the voltage signal decreased corresponding to the 950 nm LED. This is attributed to reduced signal intensities reaching the photodiode as a result of the increase in glucose absorption. Incorporating dual wavelengths for PLSR reduced the RMSE from 8.98 mg/dl to 6.49 mg/dl and also improved the R2 value from 0.97 to 0.99.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 4642
Topical term or geographic name entry element Humanities and Applied Sciences
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 18195
Co-Author Singh, Manjri
773 0# - HOST ITEM ENTRY
Title Indian journal of pure & applied physics (IJPAP)
Place, publisher, and date of publication New Delhi CSIR-NISCAIR
International Standard Serial Number 0019-5596
856 ## - ELECTRONIC LOCATION AND ACCESS
URL http://op.niscpr.res.in/index.php/IJPAP/article/view/63861
Link text Click here
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme
Koha item type Articles Abstract Database
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Permanent Location Current Location Shelving location Date acquired Barcode Date last seen Price effective from Koha item type
          School of Engineering & Technology School of Engineering & Technology Archieval Section 2022-10-01 2022-1776 2022-10-01 2022-10-01 Articles Abstract Database
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha