Method development and validation of RP-HPLC for the simultaneous estimation of escitalopram and etizolam in bulk and pharmaceutical dosage form (Record no. 7794)

000 -LEADER
fixed length control field a
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20181205144257.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 181205b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency AIKTC-KRRC
Transcribing agency AIKTC-KRRC
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 6751
Author Vadrevu, S.
245 ## - TITLE STATEMENT
Title Method development and validation of RP-HPLC for the simultaneous estimation of escitalopram and etizolam in bulk and pharmaceutical dosage form
250 ## - EDITION STATEMENT
Volume, Issue number Vol. 55 (02) February
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Mumbai
Name of publisher, distributor, etc. Indian Drug Manufacture's Association - IDMA
Year 2018
300 ## - PHYSICAL DESCRIPTION
Pagination 50-56
520 ## - SUMMARY, ETC.
Summary, etc. The developed RP-HPLC method allows rapid and precise determinations of escitalopram and etizolam in bulk and pharmaceutical dosage forms. The objective of the proposed method was to develop a simple and accurate method for the determination of escitalopram and etizolam by RP-HPLC method in pharmaceutical dosage forms & its stability indicative studies. A series of mobile phases were tried; among the various mobile phases , potassium dihydrogen phosphate buffer and dipotassium hydrogen phosphate 0.02 M, pH 3.0 : acetonitrile (20:80) is an ideal mobile phase, since it gave a good resolution and peak shapes with perfect optimization. The flow rate was optimized at less than 2 mL/min. The linearity and correlation coefficient of escitalopram and etizolam at 0-45μg/mL and 0-75μg/mL was found to be 0.998 & 0.998, respectively. The LOD was found to be 0.1 mg/mL and 0.3 mg/mL and LOQ was found to be 0.15 mg/mL and 0.45 mg/mL for escitalopram and etizolam, respectively, which represents that sensitivity of the method is high. The method was known to be accurate with the assay method. The % assay was found to be 100 % and 98%. The developed method showed a good accuracy and precision. The % RSD is for escitalopram and etizolam was found to be 1.50 and 1.22. This method shows good reproducibility of the results. Furthermore, this method was simple, sensitive, and accurate. Hence, the chromatographic method developed for escitalopram & eizolam can be effectively applied for routine analysis.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 4639
Topical term or geographic name entry element PHARMACEUTICS
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 6755
Co-Author Govindarao, K.
773 0# - HOST ITEM ENTRY
Place, publisher, and date of publication Mumbai Indian Drug Manufactures Association
Title Indian drugs
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme
Koha item type Articles Abstract Database
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Permanent Location Current Location Shelving location Date acquired Barcode Date last seen Price effective from Koha item type
          School of Pharmacy School of Pharmacy Archieval Section 2019-03-28 2018017 2019-06-19 2019-03-28 Articles Abstract Database
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.