Development of sirolimus coated eluting stent using abluminal coating technology (Record no. 7866)

000 -LEADER
fixed length control field a
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20190314093423.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 181211b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency AIKTC-KRRC
Transcribing agency AIKTC-KRRC
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 6958
Author Shah, N. V.
245 ## - TITLE STATEMENT
Title Development of sirolimus coated eluting stent using abluminal coating technology
250 ## - EDITION STATEMENT
Volume, Issue number Vol. 55 (04) April
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Mumbai
Name of publisher, distributor, etc. Indian Drug Manufacture's Association - IDMA
Year 2018
300 ## - PHYSICAL DESCRIPTION
Pagination 56-62
520 ## - SUMMARY, ETC.
Summary, etc. The current study focuses on the development of abluminal coated stent using blend of sirolimus and poly L-lactide-co-caprolactone as the biodegradable polymer. The abluminal coating of stents presume to reduce the systemic side effects and provide targeted tissue release. To compare outcome of abluminal coated stents, conformal coated stent was also prepared using similar technology. Scanning electron microscopy was carried out to differentiate the abluminal and conformal coating patterns. Both patterns showed smooth and uniform coating which remains intact with stent surface even after crimping and post-expansion. Drug content data acquired by HPLC represented uniformity of drug coating on coated stents. In vitro drug elution revealed that both coating patterns yield similar percentage of drug release however, abluminal coated stent required less amount of drug and polymer due to selective application at vascular injury area. The findings indicate that the abluminal coated stent may be the future technology for efficient delivery of certain drugs.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 4639
Topical term or geographic name entry element PHARMACEUTICS
653 ## - Keywords
Keywords Drug eluting stent
653 ## - Keywords
Keywords Biodegradable polymer
653 ## - Keywords
Keywords Abluminal coating
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 6959
Co-Author Jariwala, A. B.
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 6960
Co-Author Raval, A. J.
773 0# - HOST ITEM ENTRY
Title Indian drugs
Place, publisher, and date of publication Mumbai Indian Drug Manufactures Association
856 ## - ELECTRONIC LOCATION AND ACCESS
Link text Click here
URL https://www.indiandrugsonline.org/issuesarticle-details?id=Nzgz
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme
Koha item type Articles Abstract Database
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Permanent Location Current Location Shelving location Date acquired Barcode Date last seen Price effective from Koha item type
          School of Pharmacy School of Pharmacy Archieval Section 2019-03-28 2018046 2019-06-19 2019-03-28 Articles Abstract Database
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha