Estimation of celecoxib in human plasma by rapid and selective LC-MS/MS method for a bioequivalency study (Record no. 8442)

000 -LEADER
fixed length control field a
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20190315091738.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190306b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency AIKTC-KRRC
Transcribing agency AIKTC-KRRC
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 7864
Author Patel, Nirav P.
245 ## - TITLE STATEMENT
Title Estimation of celecoxib in human plasma by rapid and selective LC-MS/MS method for a bioequivalency study
250 ## - EDITION STATEMENT
Volume, Issue number Vol. 10(10), July-August
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. M. P.
Name of publisher, distributor, etc. Innovare Academic Sciences Pvt Ltd
Year 2018
300 ## - PHYSICAL DESCRIPTION
Pagination 16-22
520 ## - SUMMARY, ETC.
Summary, etc. Objective: A selective, sensitive and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay has been developed for the determination of celecoxib (CXB) in negative ionization mode. Methods: Celecoxib and celecoxib-D7 (CXB-D7) as internal standard (IS) were extracted from 300 μl human plasma by solid-phase extraction using strata-X SPE cartridges. Chromatographic separation was achieved on ACE C8-300 (50 × 4.0 mm, 3.0 μm) column using methanol-1.0 mmolammonium acetate solution in 80:20 (v/v) ratio. The protonated precursor to product ion transitions studied for CXB and CXB-D7 were m/z 380.0 → 315.9 and 387.0 → 323.0, respectively.Results: The limit of detection (LOD) and lower limit of quantitation of the method were 2.50 and 10.0 ng/ml respectively with a linear dynamic range of 10.0-4000 ng/ml for CXB. The intra-batch and inter-batch precision (% CV) and mean relative recovery across quality control levels is<7.2% and 85.5 % respectively. Matrix effect in human plasma, expressed as IS-normalized matrix factor ranged from 0.99-1.03. Conclusion: The method was successfully applied in healthy subjects using a single dose of 400 mg celecoxi..........
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 4639
Topical term or geographic name entry element PHARMACEUTICS
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 7865
Co-Author Sanyal, Mallika
773 0# - HOST ITEM ENTRY
Title International journal of pharmacy and pharmaceutical science
International Standard Serial Number 0975 – 1491
Place, publisher, and date of publication Bhopal Innovare Academic Sciences Pvt Ltd
856 ## - ELECTRONIC LOCATION AND ACCESS
URL https://innovareacademics.in/journals/index.php/ijpps/article/view/28289/15879
Link text Click here
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme
Koha item type Articles Abstract Database
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Permanent Location Current Location Shelving location Date acquired Barcode Date last seen Price effective from Koha item type
          School of Pharmacy School of Pharmacy Archieval Section 2019-03-30 2018412 2019-06-19 2019-03-30 Articles Abstract Database
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha