Development and validation of stability indicate RP-HPLC method for simultaneous determination of aspirin, rosuvastatin, clopidogrel in bulk and pharmaceutical dosage form (Record no. 8446)

000 -LEADER
fixed length control field a
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20190315092257.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190307b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency AIKTC-KRRC
Transcribing agency AIKTC-KRRC
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 7874
Author Pisal, Pooja
245 ## - TITLE STATEMENT
Title Development and validation of stability indicate RP-HPLC method for simultaneous determination of aspirin, rosuvastatin, clopidogrel in bulk and pharmaceutical dosage form
250 ## - EDITION STATEMENT
Volume, Issue number Vol. 10(10), July-August
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. M. P.
Name of publisher, distributor, etc. Innovare Academic Sciences Pvt Ltd
Year 2018
300 ## - PHYSICAL DESCRIPTION
Pagination 50-56
520 ## - SUMMARY, ETC.
Summary, etc. Objective:To develop a novel, accurate, precise and linear reverse phase high-performance liquid chromatography (RP-HPLC) and Stability Indicating Assay Method (SIAMs) for simultaneous, qualitative and quantitative estimation of aspirin, rosuvastatin and clopidogrel in bulk and pharmaceutical dosage form as per International Conference on Harmonization (ICH) guidelines.Method: In the present work, good chromatographic separation was achieved by isocratic method using a BISCOF HPLC C18 Results: The retention time of aspirin, rosuvastatin, and clopidogrel was found to be 4.3 min, 7.6 min and 16.6 min respectively. For linearity seven-point calibration curves were obtained in a concentration range from 1-7 μg/ml for aspirin, rosuvastatin and clopidogrel with correlation coefficient 0.999, 0.9989, 0.9988 respectively. The high recovery values (99%-101%) indicate a satisfactory accuracy. The low percent relative standard deviation (% RSD) values in the precision study reveal that the method is precise. In the present study stability indicating an RP-HPLC method for the combination was tested by degrading the drugs together under various stress condition like acid, base and neutral hydrolysis, oxidation, thermal and photolytic stress which is recommended by ICH.column (250 mm ×4.6, 5 μm) and a mobile phase consisting of water at pH 2.51 with 0.1 % (v/v) orthophosphoric acid (OPA): acetonitrile in the ratio 50:50, at a flow rate of 1 ml/min. The effluents obtained were monitored at 237 nm with the UV-visible detector.Conclusion: The developed RP-HPLC method is simple, economic, specific, accurate and precise for the simultaneous estimation of aspirin, rosuvastatin, and clopidogrel in the combined capsule dosage form. The developed stability indicating analytical meth....
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 4639
Topical term or geographic name entry element PHARMACEUTICS
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 7875
Co-Author Nigade, Ganesh
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 7876
Co-Author Kale, Amol
773 0# - HOST ITEM ENTRY
Place, publisher, and date of publication Bhopal Innovare Academic Sciences Pvt Ltd
International Standard Serial Number 0975 – 1491
Title International journal of pharmacy and pharmaceutical science
856 ## - ELECTRONIC LOCATION AND ACCESS
URL https://innovareacademics.in/journals/index.php/ijpps/article/view/28329/15886
Link text Click here
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme
Koha item type Articles Abstract Database
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Permanent Location Current Location Shelving location Date acquired Barcode Date last seen Price effective from Koha item type
          School of Pharmacy School of Pharmacy Archieval Section 2019-03-30 2018416 2019-06-19 2019-03-30 Articles Abstract Database
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha