Base isolation versus dual design philosophy for seismic design of buildings: Preliminary case study (Record no. 8524)

000 -LEADER
fixed length control field a
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20190315143939.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190315b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency AIKTC-KRRC
Transcribing agency AIKTC-KRRC
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 8053
Author Karmakar, Soubhagya
245 ## - TITLE STATEMENT
Title Base isolation versus dual design philosophy for seismic design of buildings: Preliminary case study
250 ## - EDITION STATEMENT
Volume, Issue number Vol. 99(4), December
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kolkata
Name of publisher, distributor, etc. Springer
Year 2018
300 ## - PHYSICAL DESCRIPTION
Pagination 627-635p.
520 ## - SUMMARY, ETC.
Summary, etc. The structures are generally designed through dual design philosophy or more broadly known as performance-based design. In this philosophy, the strength is limited to minimize the cost relying on damage-absorbing capacity or ductility capacity of structural members. Still lack of understanding of many issues of nonlinear behavior of structural member makes this method an interesting topic for further research. Base isolation technique is not possible to adopt many a times due to financial limitation. However, this technique may be made more economic and practically implementable through further research. Further, design methodology can also be simplified. Thus, possibly such methodology can be used for an identified class of buildings through further research in this direction. Example case studies presented in the paper for both structures on base isolator and those designed by dual design philosophy clearly indicate intuitively understandable findings. Finally, the paper provides a qualitative insight for economically viable use of base isolation system. It also shows the possibilities of how inelastic excursion-based dual design philosophy can be simultaneously used along with base isolation for reducing the cost further.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 4621
Topical term or geographic name entry element Civil Engineering
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 8054
Co-Author Sumit Kumar
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 1320
Co-Author Dutta, Sekhar Chandra
773 0# - HOST ITEM ENTRY
Title Journal of the institution of engineers (India) Series A
Place, publisher, and date of publication Dordrecht Springer
International Standard Serial Number 2250-2149
856 ## - ELECTRONIC LOCATION AND ACCESS
URL https://link.springer.com/article/10.1007/s40030-018-0320-9
Link text Click here
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme
Koha item type Articles Abstract Database
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Permanent Location Current Location Shelving location Date acquired Barcode Date last seen Price effective from Koha item type
          School of Engineering & Technology School of Engineering & Technology Archieval Section 2019-03-29 2018206 2019-06-10 2019-03-29 Articles Abstract Database
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha