Ecological Footprint Reduction of Building Envelope in a Tropical Climate (Record no. 9145)

000 -LEADER
fixed length control field a
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20190530101503.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 190530b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency AIKTC-KRRC
Transcribing agency AIKTC-KRRC
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 8939
Author Dilawar Husain
245 ## - TITLE STATEMENT
Title Ecological Footprint Reduction of Building Envelope in a Tropical Climate
250 ## - EDITION STATEMENT
Volume, Issue number Vol. 100(1), March
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. New York
Name of publisher, distributor, etc. Springer
Year 2019
300 ## - PHYSICAL DESCRIPTION
Pagination 41-48p.
520 ## - SUMMARY, ETC.
Summary, etc. Built envelope (external wall and roof) significantly influences the environment during construction as well as operational phase of the building. The present study examines environmental impact reduction of a building in tropical climate through low-impact materials and green roof. Ecological footprint (EF) is a globally recognized assessment tool that assesses the environmental impact of the human activities. EF tool was used in this study on two different design models: conventional design (Model I) and modified design (Model II). It was observed that modified design reduces the EF of the built envelope significantly. By taking the built envelope as the research object, this study experimentally examines the thermal characteristics of the external wall/roof structure and analyzes the materials used in Indian buildings for a modified design. For external wall surface area, the constructional EF of the Model I and Model II is 0.0091 and 0.0049 gha/m2, respectively. For roof surface area, the constructional EF of the Model I and Model II is 0.0064 and 0.0071 gha/m2, respectively. The monthly operational EF reduction potential of external wall and roof of the Model II as compared to Model I is in the range of 25–30.1% and 61.9–67.1%, respectively. The constructional cost per unit external wall surface area of the Model II is 10% higher than the cost of conventional external wall (Model I), while the constructional cost per unit green roof surface area of the Model II is 15.6% higher than conventional roof of the Model I.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 4621
Topical term or geographic name entry element Civil Engineering
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 8940
Co-Author Ravi Prakash
773 0# - HOST ITEM ENTRY
International Standard Serial Number 2250-2149
Title Journal of the institution of engineers (India) Series A
Place, publisher, and date of publication Dordrecht Springer
856 ## - ELECTRONIC LOCATION AND ACCESS
URL https://link.springer.com/article/10.1007/s40030-018-0333-4
Link text Click here
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme
Koha item type Articles Abstract Database
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Permanent Location Current Location Shelving location Date acquired Barcode Date last seen Price effective from Koha item type
          School of Engineering & Technology School of Engineering & Technology Archieval Section 2019-05-30 2018594 2019-06-10 2019-05-30 Articles Abstract Database
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha