Residual strength and microstructural identification of slurry infiltrated fibrous concrete (sifcon) at elevated temperature (Record no. 9569)

000 -LEADER
fixed length control field a
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20191001100525.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 191001b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency AIKTC-KRRC
Transcribing agency AIKTC-KRRC
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 9677
Author Shelorkar, A. P.
245 ## - TITLE STATEMENT
Title Residual strength and microstructural identification of slurry infiltrated fibrous concrete (sifcon) at elevated temperature
250 ## - EDITION STATEMENT
Volume, Issue number Vol.93(08), August
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Thane
Name of publisher, distributor, etc. ACC LTD
Year 2019
300 ## - PHYSICAL DESCRIPTION
Pagination 67-77p.
520 ## - SUMMARY, ETC.
Summary, etc. This study investigates the residual strength and microstructural identification of slurry infiltrated fibrous concrete at elevated temperature. The mechanical properties of slurry infiltrated fibrous concrete specimen are found by replacing cement by fly ash and metakaolin in the proportions of 5, 7.5 and 10% by weight of cement. The influence of raised temperature, up to 600°C, on the compressive strength and microstructure of metakaolin and fly ash blended slurry infiltrated fibrous concrete (SIFCON) has been investigated in this study. Two hundred twenty-eight cube specimens of slurry infiltrated fibrous concrete were tested at 20°C and 200-600°C. In this investigation, control specimen, residual compressive strength for 200°C, 400°C and 600°C elevated temperatures as 77, 55 and 20%, respectively, and metakaolin blended slurry infiltrated fibrous concrete residual compressive strength shows 95, 88 and 74%, respectively. Based on the experimental results, this study provides an aid to estimate the mechanical properties of slurry infiltrated fibrous concrete exposed to high temperature.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 4621
Topical term or geographic name entry element Civil Engineering
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 9678
Co-Author Jadhao, P. D.
773 0# - HOST ITEM ENTRY
Title Indian Concrete Journal
Place, publisher, and date of publication Thane ACC Limited
Record control number icj
856 ## - ELECTRONIC LOCATION AND ACCESS
URL https://www.icjonline.com/editionabstract_detail/082019
Link text Click here
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme
Koha item type Articles Abstract Database
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Permanent Location Current Location Shelving location Date acquired Barcode Date last seen Price effective from Koha item type
          School of Engineering & Technology (PG) School of Engineering & Technology (PG) Archieval Section 2019-10-01 2019752 2019-10-01 2019-10-01 Articles Abstract Database
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha