Comparison of Mean Centering of Ratio Spectra Based Spectrophotometric Approach and HPLC Method for Quantitative Determination of Pirenoxine in the Presence of Methylparaben and Propylparaben (Record no. 9863)

000 -LEADER
fixed length control field a
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20191025153637.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 191025b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency AIKTC-KRRC
Transcribing agency AIKTC-KRRC
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 10137
Author Wasito, Hendri
245 ## - TITLE STATEMENT
Title Comparison of Mean Centering of Ratio Spectra Based Spectrophotometric Approach and HPLC Method for Quantitative Determination of Pirenoxine in the Presence of Methylparaben and Propylparaben
250 ## - EDITION STATEMENT
Volume, Issue number Vol.52(2), Apr-Jun
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Bengaluru
Name of publisher, distributor, etc. Indian journal of pharmaceutical education and research
Year 2018
300 ## - PHYSICAL DESCRIPTION
Pagination 284-292p.
520 ## - SUMMARY, ETC.
Summary, etc. Objective: The mean centering of ratio spectra method (MCR) was developed for determination of pirenoxine in the presence of methylparaben and propylparaben. Background: The UV spectrum of pirenoxine was suffered from spectra overlapping of methylparaben and propylparaben, the preservatives used in the eye drop formulation. Since, MCR method was introduced to overcome this limitation. Methods: The developed MCR method was performed using 39 synthetic mixtures of pirenoxine, methylparaben and propylparaben. The amplitudes at 320 nm of the second ratio spectra were used to construct a calibration model for pirenoxine. Performance characteristics of the method such as linearity, accuracy and precision, were calculated. A high-performance liquid chromatography (HPLC) method was also developed and validated. Then, two methods were used to determine a set of commercial eye drop samples for comparison. Results:The developed and validated MCR method was simple, rapid, accurate, and precise and could be applied to determine pirenoxine in eye drop samples. Measurement of pirenoxine in eye drop samples by MCR and HPLC methods were not significantly different (P-value = 0.21).
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 4639
Topical term or geographic name entry element PHARMACEUTICS
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 10138
Co-Author Buranaphalin, Sawanya
773 0# - HOST ITEM ENTRY
Place, publisher, and date of publication Bengluru Association of Pharmaceutical Teachers of India (APTI)
Title Indian journal of pharmaceutical education and research
International Standard Serial Number 0019-5464
856 ## - ELECTRONIC LOCATION AND ACCESS
URL https://www.ijper.org/sites/default/files/IndJPhaEdRes_52_2_284.pdf
Link text Click here
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme
Koha item type Articles Abstract Database
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Permanent Location Current Location Shelving location Date acquired Barcode Date last seen Price effective from Koha item type
          School of Pharmacy School of Pharmacy Archieval Section 2019-10-25 2020014 2019-10-25 2019-10-25 Articles Abstract Database
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha