Publisher: Mumbai Indian Drug Manufacture's Association - IDMA 2019Edition: Vol. 56 (08).Description: 49-56p.Subject(s): PHARMACEUTICSOnline resources: Click here In: Indian drugsSummary: A simple, accurate, precise, reproducible and economic method developed and validated for the simultaneous estimation of teneligliptine hydrobromide hydrate (TENE) and metformin hydrochloride (MET HCl) in pharmaceutical dosage form. TENE and MET HCl were estimated on Thermoscientific C18 column using mobile phase 0.01M PDP: methanol (45:55 % v/v) (pH 3.5 adjusted with 5% acetic acid) at flow rate 1.0 mL/min. Detection was carried out at 254 nm. The retention time of teneligliptine hydrobromide hydrate and metformin hydrochloride were 7.77 min and 2.64 min, respectively. The linearity was found to be 4-12 μg/mL and 100-300 μg/mL for TENE and MET HCl respectively. R2 value was found to be 0.998 and 0.995. For the assay method % recovery was found in the range of 98.16 – 101 for TENE and MET HCl. The LOD and LOQ were found to be 0.3527 and 1.0690 for TENE and 0.5077 and 1.538 for MET HCl respectively. Method was validated as per ICH guidelines.
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Pharmacy
Archieval Section
Not for loan 2020456
Total holds: 0

A simple, accurate, precise, reproducible and economic method developed and validated for the simultaneous estimation of teneligliptine hydrobromide hydrate (TENE) and metformin hydrochloride (MET HCl) in pharmaceutical dosage form. TENE and MET HCl were estimated on Thermoscientific C18 column using mobile phase 0.01M PDP: methanol (45:55 % v/v) (pH 3.5 adjusted with 5% acetic acid) at flow rate 1.0 mL/min. Detection was carried out at 254 nm. The retention time of teneligliptine hydrobromide hydrate and metformin hydrochloride were 7.77 min and 2.64 min, respectively. The linearity was found to be 4-12 μg/mL and 100-300 μg/mL for TENE and MET HCl respectively. R2 value was found to be 0.998 and 0.995. For the assay method % recovery was found in the range of 98.16 – 101 for TENE and MET HCl. The LOD and LOQ were found to be 0.3527 and 1.0690 for TENE and 0.5077 and 1.538 for MET HCl respectively. Method was validated as per ICH guidelines.

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha