High performance liquid chromatographic- diode array detector method for simultaneous estimation of escitalopram oxalate and flupentixol dihydrochloride in combination
By: Gawande, V. V.
Contributor(s): Chandewar, A. V.
Publisher: Mumbai Indian Drug Manufacture's Association - IDMA 2019Edition: Vol. 56 (08).Description: 61-68p.Subject(s): PHARMACEUTICSOnline resources: Click here In: Indian drugsSummary: The proposed work involves High Performance Liquid Chromatographic – Diode Array Detector method for estimation of escitalopram oxalate and flupentixol dihydrochloride in combination. The analytes were resolved on Waters C18 Xterra column (50 × 4.6 mm id, particle size 3.5 μm) with mobile phase composition of water (containing 0.2 % triethylamine pH adjusted to 2.5 with orthophosphoric acid): acetonitrile: methanol (62:28:10 % v/v/v). The flow rate kept was 1.0 mL/min opting isocratic mode and eluents were tracked down at 230 nm. The retention times for both the drugs were 1.38±0.21 and 2.98±0.41, respectively. Standard addition method was employed for the analysis of flupentixol dihydrochloride. ICH guidelines were followed to validate the method. The method assured linearity in concentration range of 50-150 μg/mL and 2.5-7.5 μg/mL for ESC and FLU, respectively. The method assured high degree of precision and accuracy. The method was proved to be robust by assessing robustness parameters.Item type | Current location | Call number | Status | Date due | Barcode | Item holds |
---|---|---|---|---|---|---|
Articles Abstract Database | School of Pharmacy Archieval Section | Not for loan | 2020486 |
The proposed work involves High Performance Liquid Chromatographic – Diode Array Detector method for estimation of escitalopram oxalate and flupentixol dihydrochloride in combination. The analytes were resolved on Waters C18 Xterra column (50 × 4.6 mm id, particle size 3.5 μm) with mobile phase composition of water (containing 0.2 % triethylamine pH adjusted to 2.5 with orthophosphoric acid): acetonitrile: methanol (62:28:10 % v/v/v). The flow rate kept was 1.0 mL/min opting isocratic mode and eluents were tracked down at 230 nm. The retention times for both the drugs were 1.38±0.21 and 2.98±0.41, respectively. Standard addition method was employed for the analysis of flupentixol dihydrochloride. ICH guidelines were followed to validate the method. The method assured linearity in concentration range of 50-150 μg/mL and 2.5-7.5 μg/mL for ESC and FLU, respectively. The method assured high degree of precision and accuracy. The method was proved to be robust by assessing robustness parameters.
There are no comments for this item.