High performance liquid chromatographic- diode array detector method for simultaneous estimation of escitalopram oxalate and flupentixol dihydrochloride in combination

By: Gawande, V. V.
Contributor(s): Chandewar, A. V.
Publisher: Mumbai Indian Drug Manufacture's Association - IDMA 2019Edition: Vol. 56 (08).Description: 61-68p.Subject(s): PHARMACEUTICSOnline resources: Click here In: Indian drugsSummary: The proposed work involves High Performance Liquid Chromatographic – Diode Array Detector method for estimation of escitalopram oxalate and flupentixol dihydrochloride in combination. The analytes were resolved on Waters C18 Xterra column (50 × 4.6 mm id, particle size 3.5 μm) with mobile phase composition of water (containing 0.2 % triethylamine pH adjusted to 2.5 with orthophosphoric acid): acetonitrile: methanol (62:28:10 % v/v/v). The flow rate kept was 1.0 mL/min opting isocratic mode and eluents were tracked down at 230 nm. The retention times for both the drugs were 1.38±0.21 and 2.98±0.41, respectively. Standard addition method was employed for the analysis of flupentixol dihydrochloride. ICH guidelines were followed to validate the method. The method assured linearity in concentration range of 50-150 μg/mL and 2.5-7.5 μg/mL for ESC and FLU, respectively. The method assured high degree of precision and accuracy. The method was proved to be robust by assessing robustness parameters.
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Pharmacy
Archieval Section
Not for loan 2020486
Total holds: 0

The proposed work involves High Performance Liquid Chromatographic – Diode Array Detector method for estimation of escitalopram oxalate and flupentixol dihydrochloride in combination. The analytes were resolved on Waters C18 Xterra column (50 × 4.6 mm id, particle size 3.5 μm) with mobile phase composition of water (containing 0.2 % triethylamine pH adjusted to 2.5 with orthophosphoric acid): acetonitrile: methanol (62:28:10 % v/v/v). The flow rate kept was 1.0 mL/min opting isocratic mode and eluents were tracked down at 230 nm. The retention times for both the drugs were 1.38±0.21 and 2.98±0.41, respectively. Standard addition method was employed for the analysis of flupentixol dihydrochloride. ICH guidelines were followed to validate the method. The method assured linearity in concentration range of 50-150 μg/mL and 2.5-7.5 μg/mL for ESC and FLU, respectively. The method assured high degree of precision and accuracy. The method was proved to be robust by assessing robustness parameters.

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha