Normal view MARC view ISBD view

Performance Step-up of Nuclear Greater Power Grid by HVAC-3HVDC Line

By: Sahu, Pankaj Kumar.
Publisher: New Delhi Journals Pub 2019Edition: Vol.(1), Jan-Apr.Description: 1-14p.Subject(s): Electrical EngineeringOnline resources: Click here In: Journal of power electronics and power systemsSummary: This research work is done for performance step-up of nuclear greater power by HVAC-3HVDC line when load disturbance occurs in power grid-1. Three types of tie lines, HVAC-3HVDC, HVAC-2HVDC and HVAC-1HVDC parallel tie lines are applied for performance step-up of 12-area two interconnected nuclear greater power grids. For synchronizing purpose of nuclear greater power grid, this research work proves that HVAC-3HVDC parallel tie line is better as compared to the HVAC-2HVDC and HVAC-1HVDC parallel tie line. This project work also proves the HVAC-2HVDC parallel tie line is better as compared to the HVAC-1HVDC parallel tie line. Quality of all three types of tie line is judged by the frequency deviation of 12-area two interconnected nuclear greater power grid when load disturbance occurs in power grid-1. The major advantage of this research work is the performance of nuclear greater power grid is stepped-up by HVAC-3HVDC line without any high-tech controller.
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Engineering & Technology
Archieval Section
Not for loan 2020558
Total holds: 0

This research work is done for performance step-up of nuclear greater power by HVAC-3HVDC line when load disturbance occurs in power grid-1. Three types of tie lines, HVAC-3HVDC, HVAC-2HVDC and HVAC-1HVDC parallel tie lines are applied for performance step-up of 12-area two interconnected nuclear greater power grids. For synchronizing purpose of nuclear greater power grid, this research work proves that HVAC-3HVDC parallel tie line is better as compared to the HVAC-2HVDC and HVAC-1HVDC parallel tie line. This project work also proves the HVAC-2HVDC parallel tie line is better as compared to the HVAC-1HVDC parallel tie line. Quality of all three types of tie line is judged by the frequency deviation of 12-area two interconnected nuclear greater power grid when load disturbance occurs in power grid-1. The major advantage of this research work is the performance of nuclear greater power grid is stepped-up by HVAC-3HVDC line without any high-tech controller.

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha