Novel Analytical Method development and validation for estimation of bromofenac sodium in bulk and pharmaceutical dosage form by Derivative and AUC spectroscopic method

By: Raghu S.
Contributor(s): Muneer, S.
Publisher: Mumbai Indian Drug Manufacture's Association - IDMA 2019Edition: Vol.56(01), Jan.Description: 87-90p.Subject(s): PHARMACEUTICSOnline resources: Click here In: Indian drugsSummary: The present study was carried out to develop a simple and reliable derivative spectrophotometric method for the determination of bromofenac sodium in pharmaceutical dosage forms .The solutions of standard and the sample were prepared in distilled water The quantitative determination of the drug was carried out with zero order derivative (method A) values measured at 268 nm and first order (method B) derivative values measured at 258 nm , and two wavelengths 262nm and 274nm were selected for the determination AUC (method C) of integrated areas. Calibration graphs constructed at their wavelengths of determination, were linear within the concentration range of 2-12 μg/mL (r2 = 0.999) for zero order and (r2 = 0.997) first order derivative spectrophotometric method. No significant difference between the performance of the proposed methods regarding the mean values and standard deviations and is suitable for the routine quality control application of bromofenac sodium in its pharmaceutical formulations.
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Pharmacy
Archieval Section
Not for loan 2020987
Total holds: 0

The present study was carried out to develop a simple and reliable derivative spectrophotometric method for the determination of bromofenac sodium in pharmaceutical dosage forms .The solutions of standard and the sample were prepared in distilled water The quantitative determination of the drug was carried out with zero order derivative (method A) values measured at 268 nm and first order (method B) derivative values measured at 258 nm , and two wavelengths 262nm and 274nm were selected for the determination AUC (method C) of integrated areas. Calibration graphs constructed at their wavelengths of determination, were linear within the concentration range of 2-12 μg/mL (r2 = 0.999) for zero order and (r2 = 0.997) first order derivative spectrophotometric method. No significant difference between the performance of the proposed methods regarding the mean values and standard deviations and is suitable for the routine quality control application of bromofenac sodium in its pharmaceutical formulations.

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha