Normal view MARC view ISBD view

New Approach to the Laplace-Domain Transient Analysis of Non-Uniform Lines with Application to Power Line Towers

By: Mohamed M.Saied.
Publisher: Noida STM Journals 2019Edition: Vol.9(3), Sep-Dec.Description: 1-10p.Subject(s): Electrical EngineeringOnline resources: Click here In: Trends in electrical engineering (TEE)Summary: This paper presents a new technique for the Laplace-domain analysis ofthe electromagnetic transients in non-uniform lines with special consideration of high voltage power line towers. The derived partial differential equations governing the voltage and current distributions, as functions of both the location and time, are solved by an efficient Mathematica computercode based on parametric functions. The applicability of the proposed direct distributed-parameter simulation is demonstrated. Theresults are in good agreement with those obtained through the application of other more sophisticated solution methods available in the literature. Several case studies are investigated in order to indicate the impact of the different affecting parameters such as the towers’ footing termination and the time waveform of the lightning strike.
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Engineering & Technology
Archieval Section
Not for loan 2020-2021215
Total holds: 0

This paper presents a new technique for the Laplace-domain analysis ofthe electromagnetic transients in non-uniform lines with special consideration of high voltage power line towers. The derived partial differential equations governing the voltage and current distributions, as functions of both the location and time, are solved by an efficient Mathematica computercode based on parametric functions. The applicability of the proposed direct distributed-parameter simulation is demonstrated. Theresults are in good agreement with those obtained through the application of other more sophisticated solution methods available in the literature. Several case studies are investigated in order to indicate the impact of the different affecting parameters such as the towers’ footing termination and the time waveform of the lightning strike.

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha