Publisher: New York Springer 2021Edition: Vol102(2), June.Description: 545-564p.Subject(s): Civil EngineeringOnline resources: Click hrer In: Journal of the institution of engineers (India): Series ASummary: Full scale compartment fire studies have been conducted with plywood board as lining material on walls. The compartment was of size 3.6 m long × 2.4 m wide × 2.4 m high with a doorway of size 0.8 m wide × 2.0 m high with hood as per ISO 9705. Standard propane burner ignition source of size 0.3 m × 0.3 m was set to produce a heat release rate (HRR) of 40 kW in the first 5 min and of 160 kW in the next 10 min at the room corner. K–type thermocouples, heat flux sensor, pressure transducers and flue gas analyzers were used to measure temperatures, radiation, differential pressure and toxic species concentrations of hot gases at different locations within the compartment and hood. Peak heat release rates, flashover condition and gas concentrations were measured in transient condition and compared with tenability limits of fire hazards.
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Engineering & Technology (PG)
Archieval Section
Not for loan 2021-2022055
Total holds: 0

Full scale compartment fire studies have been conducted with plywood board as lining material on walls. The compartment was of size 3.6 m long × 2.4 m wide × 2.4 m high with a doorway of size 0.8 m wide × 2.0 m high with hood as per ISO 9705. Standard propane burner ignition source of size 0.3 m × 0.3 m was set to produce a heat release rate (HRR) of 40 kW in the first 5 min and of 160 kW in the next 10 min at the room corner. K–type thermocouples, heat flux sensor, pressure transducers and flue gas analyzers were used to measure temperatures, radiation, differential pressure and toxic species concentrations of hot gases at different locations within the compartment and hood. Peak heat release rates, flashover condition and gas concentrations were measured in transient condition and compared with tenability limits of fire hazards.

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha