Publisher: M P Innovare Academic Sciences Pvt Ltd 2021Edition: Vol.13(7).Description: 49-58p.Subject(s): PHARMACEUTICSOnline resources: Click here In: International journal of pharmacy and pharmaceutical scienceSummary: Objective: The principal objective of this study is to develop and validate a simple, new, fast, selective, precise, and economic stability-indicating the RP-HPLC method for the simultaneous estimation of Ethinyl estradiol and Gestodene in a bulk and pharmaceutical dosage form.Methods: The present method was developed and validated on a Waters HPLC system using Phenomenex Gemini C18(250 mm × 4.6 mm i.d., 5 μm particle size) column and mobile phase composition of phosphate buffer: Acetonitrile (75:25 v/v) and the pH was adjusted to 3.6 using dilute orthophosphoric acid. The system was regulated at 1.0 ml/min flow rate at 237 nm UV detection.Results: The two drugs Ethinyl Estradiol and Gestodene, were eluted at 1.788 min and 3.475 min retention time, respectively. The analytical parameters such as accuracy, precision, linearity, LOD, LOQ, ruggedness, and robustness were used for validating the developed method according to International Conference on Harmonisation [ICH] guidelines. Linearity was exhibited over the concentration range of 10-50μg/ml and 25-125μg/ml for Ethinyl Estradiol and Gestodene, respectively. The method revealed the Limit of Detection and Quantitation values for Ethinyl Estradiol and Gestodene were 1.399μg/ml, 3.909μg/ml and 4.24μg/ml, 11.85μg/ml, respectively. The stress testing was carried out to give rise to degradation products by exposing the drugs to acid, alkali, thermal, oxidative, photolytic, and hydrolytic degradation. The obtained data showed that the content of Active pharmaceutical ingredients and the degradation products were successfully separated without any interference, which confirmed the stability-indicating nature of the developed method.Conclusion: The new, simple, rapid, selective, precise, and economic stability-indicating RP-HPLC method has been successfully developed and validated. It can be satisfactorily applied for the periodic laboratory quantitative estimation of Ethinyl Estradiol and Gestodene in formulations and active pharmaceutical ingredients
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Pharmacy
Archieval Section
Not for loan 2021-2022534
Total holds: 0

Objective: The principal objective of this study is to develop and validate a simple, new, fast, selective, precise, and economic stability-indicating the RP-HPLC method for the simultaneous estimation of Ethinyl estradiol and Gestodene in a bulk and pharmaceutical dosage form.Methods: The present method was developed and validated on a Waters HPLC system using Phenomenex Gemini C18(250 mm × 4.6 mm i.d., 5 μm particle size) column and mobile phase composition of phosphate buffer: Acetonitrile (75:25 v/v) and the pH was adjusted to 3.6 using dilute orthophosphoric acid. The system was regulated at 1.0 ml/min flow rate at 237 nm UV detection.Results: The two drugs Ethinyl Estradiol and Gestodene, were eluted at 1.788 min and 3.475 min retention time, respectively. The analytical parameters such as accuracy, precision, linearity, LOD, LOQ, ruggedness, and robustness were used for validating the developed method according to International Conference on Harmonisation [ICH] guidelines. Linearity was exhibited over the concentration range of 10-50μg/ml and 25-125μg/ml for Ethinyl Estradiol and Gestodene, respectively. The method revealed the Limit of Detection and Quantitation values for Ethinyl Estradiol and Gestodene were 1.399μg/ml, 3.909μg/ml and 4.24μg/ml, 11.85μg/ml, respectively. The stress testing was carried out to give rise to degradation products by exposing the drugs to acid, alkali, thermal, oxidative, photolytic, and hydrolytic degradation. The obtained data showed that the content of Active pharmaceutical ingredients and the degradation products were successfully separated without any interference, which confirmed the stability-indicating nature of the developed method.Conclusion: The new, simple, rapid, selective, precise, and economic stability-indicating RP-HPLC method has been successfully developed and validated. It can be satisfactorily applied for the periodic laboratory quantitative estimation of Ethinyl Estradiol and Gestodene in formulations and active pharmaceutical ingredients

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha