Normal view MARC view ISBD view

Quality-by-design based development and validation of stability indicating method by uplc method for impurities of simvastatin from drug and pharmaceutical dosage form

By: Desai, M. M.
Contributor(s): Nikalje, Anna Pratima G.
Publisher: Mumbai Indian Journal of Pharmaceutical Science 2021Edition: Vol.83(1), Jan-Feb.Description: 110-119p.Subject(s): PHARMACEUTICSOnline resources: Click here In: Indian journal of pharmaceutical sciencesSummary: A rapid, robust and accurate ultra-high performance liquid chromatographic method was developed and validated for determination of impurities of simvastatin in drug and its pharmaceutical formulation. A systematic Quality-by-design approach was used for method development with the Fusion AE TM software, to screen and optimize the column, mobile phase, column temperature, gradient time and other chromatographic conditions. The optimized method uses Waters Acquity Charged Surface Hybrid, Octadecylsilane C18 (1.7μm×2.1 mm×100 mm) column with gradient elution. Orthophosphoric acid pH was adjusted to 4.5 with triethylamine and acetonitrile with a ratio of (80:20) was used as mobile phase A, whereas methanol:acetonitrile (20:80) as mobile phase B, with a flow rate of 0.35 ml/min. Ultra Violet detector was programmed at 238 nm with a runtime of 13 min, wherein all the impurities were well resolved and were separated from main peak of simvastatin. The method was validated for accuracy, repeatability, reproducibility and robustness. All the validation parameters were in acceptable range. The linearity, limit of detection and limit of quantitation was established for all the impurities and for simvastatin. The method was also applied suitably for determining the degradation products of simvastatin using stress degradation studies.
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Pharmacy
Archieval Section
Not for loan 2021-2022632
Total holds: 0

A rapid, robust and accurate ultra-high performance liquid chromatographic method was developed
and validated for determination of impurities of simvastatin in drug and its pharmaceutical formulation.
A systematic Quality-by-design approach was used for method development with the Fusion AE TM
software, to screen and optimize the column, mobile phase, column temperature, gradient time and
other chromatographic conditions. The optimized method uses Waters Acquity Charged Surface Hybrid,
Octadecylsilane C18 (1.7μm×2.1 mm×100 mm) column with gradient elution. Orthophosphoric acid pH
was adjusted to 4.5 with triethylamine and acetonitrile with a ratio of (80:20) was used as mobile phase
A, whereas methanol:acetonitrile (20:80) as mobile phase B, with a flow rate of 0.35 ml/min. Ultra Violet
detector was programmed at 238 nm with a runtime of 13 min, wherein all the impurities were well resolved
and were separated from main peak of simvastatin. The method was validated for accuracy, repeatability,
reproducibility and robustness. All the validation parameters were in acceptable range. The linearity,
limit of detection and limit of quantitation was established for all the impurities and for simvastatin. The
method was also applied suitably for determining the degradation products of simvastatin using stress
degradation studies.

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha