Normal view MARC view ISBD view

Evaluation of mechanical strength after compression of metformin 500mg tablets produced by different wet routes

By: Nascimento, Natalia C. D. O.
Contributor(s): Boldo, Emerson Mario.
Publisher: M P Innovare Academic Sciences Pvt Ltd 2021Edition: Vol.13(3).Description: 30-34p.Subject(s): PHARMACEUTICSOnline resources: Click here In: International journal of pharmacy and pharmaceutical scienceSummary: Objective: This work evaluated the post-compression hardness gain of Metformin tablets made from two granulates of the same formulation, but with different formation principles, one by the fluidized bed and the other in a V-shaped mixer. Methods: The base granulate for the production of the tablets was prepared using Metformin HCL as the main active ingredient. After compression, the prepared tablets were tested with different evaluation parameters like relative humidity, apparent and compacted density, granulometric dispersion, hardness, moisture content, and friability for complete characterization.Results: All prepared samples were within the pre-established humidity ranges (MT1 = 3.31%, MT2 = 2.72%, MT3 = 1.73%, LF1 = 3.25%, LF2 = 2.43% and LF3 = 1.79%). The density determination showed that the granules produced in the fluidized bed are less dense than those of the V mixer. LF2 sample had an apparent density of 0.525 g/ml and a compacted density of 0.546 g/ml, while the MT2 sample had an apparent density of 0.711 g/ml and a compacted density of 0.738 g/ml, corroborating the greater porosity of granules produced in a fluidized bed. It was found that there is a difference in the increase in hardness between the two granulation methods. The tablets manufactured from the granules elaborated in a V-shaped mixer showed a greater gain in comparison with those produced in the fluid bed. The MT1 sample had the highest gain percentage, reaching 99.47%, 48 h after compression. The MT2 sample obtained, for the same time, 76.34%, at a much slower speed than MT1. As for the other samples, all increased between 24 and 42%. These results are justified by the migration of agglutination liquid that occurs during the drying step.Conclusion: This work demonstrated that the product Metformin 500 mg tablet has increased hardness after compression, with most significancein the first hour after the procedure.Keywords: Hardness, Post-compression, Povidone, Fluidized bed, V blenderIt was possible to verify that the tablets made from the granules produced in a V-shaped mixer have a greater increase in hardness than those produced by the fluidized bed, in the same humidity range.
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Pharmacy
Archieval Section
Not for loan 2022-0458
Total holds: 0

Objective: This work evaluated the post-compression hardness gain of Metformin tablets made from two granulates of the same formulation, but with different formation principles, one by the fluidized bed and the other in a V-shaped mixer. Methods: The base granulate for the production of the tablets was prepared using Metformin HCL as the main active ingredient. After compression, the prepared tablets were tested with different evaluation parameters like relative humidity, apparent and compacted density, granulometric dispersion, hardness, moisture content, and friability for complete characterization.Results: All prepared samples were within the pre-established humidity ranges (MT1 = 3.31%, MT2 = 2.72%, MT3 = 1.73%, LF1 = 3.25%, LF2 = 2.43% and LF3 = 1.79%). The density determination showed that the granules produced in the fluidized bed are less dense than those of the V mixer. LF2 sample had an apparent density of 0.525 g/ml and a compacted density of 0.546 g/ml, while the MT2 sample had an apparent density of 0.711 g/ml and a compacted density of 0.738 g/ml, corroborating the greater porosity of granules produced in a fluidized bed. It was found that there is a difference in the increase in hardness between the two granulation methods. The tablets manufactured from the granules elaborated in a V-shaped mixer showed a greater gain in comparison with those produced in the fluid bed. The MT1 sample had the highest gain percentage, reaching 99.47%, 48 h after compression. The MT2 sample obtained, for the same time, 76.34%, at a much slower speed than MT1. As for the other samples, all increased between 24 and 42%. These results are justified by the migration of agglutination liquid that occurs during the drying step.Conclusion: This work demonstrated that the product Metformin 500 mg tablet has increased hardness after compression, with most significancein the first hour after the procedure.Keywords: Hardness, Post-compression, Povidone, Fluidized bed, V blenderIt was possible to verify that the tablets made from the granules produced in a V-shaped mixer have a greater increase in hardness than those produced by the fluidized bed, in the same humidity range.

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha