Normal view MARC view ISBD view

Statistical switching overvoltages of 1200 kV UHV AC transmission line

By: Reddy, Ramchandra Annadi.
Contributor(s): Patsa, Chandra Sekhar.
Publisher: New York Springer 2022Edition: Vol.103(1), Feb.Description: 189-195p.Subject(s): Humanities and Applied SciencesOnline resources: Click here In: Journal of the institution of engineers (India): Series BSummary: To transport large power over long distances to meet higher demands requires UHV AC transmission systems. In the insulation design of UHV AC power transmission systems, it is important to know the magnitude of switching overvoltages that may occur. The need to withstand the switching surges can affect the cost of a transmission system, and hence, an estimate of the switching overvoltages under various conditions of operation is important. In this paper, the magnitude of switching overvoltages generated on the world’s first 1200 kV UHV AC transmission line is estimated due to line energization, line re-energization, single-line-to-ground fault initiation and fault clearing switching operations by varying different parameters. Statistical analysis is performed on these overvoltages to obtain characteristic parameters of statistical distribution of the overvoltages. The switching operations are simulated using a digital programme like PSCAD/EMTDC.
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Engineering & Technology
Archieval Section
Not for loan 2022-1584
Total holds: 0

To transport large power over long distances to meet higher demands requires UHV AC transmission systems. In the insulation design of UHV AC power transmission systems, it is important to know the magnitude of switching overvoltages that may occur. The need to withstand the switching surges can affect the cost of a transmission system, and hence, an estimate of the switching overvoltages under various conditions of operation is important. In this paper, the magnitude of switching overvoltages generated on the world’s first 1200 kV UHV AC transmission line is estimated due to line energization, line re-energization, single-line-to-ground fault initiation and fault clearing switching operations by varying different parameters. Statistical analysis is performed on these overvoltages to obtain characteristic parameters of statistical distribution of the overvoltages. The switching operations are simulated using a digital programme like PSCAD/EMTDC.

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha