Comparison of anti-islanding protection in single- and three-phase solar grid-connected string inverters

By: Jeykishan Kumar, K.
Publisher: New York Springer 2022Edition: Vol.103(1), Feb.Description: 225-235p.Subject(s): Humanities and Applied SciencesOnline resources: Click here In: Journal of the institution of engineers (India): Series BSummary: Anti-islanding protection plays a major role in grid-connected inverters which are based either on solar PV or other renewable energy resources when they are connected to the utility. In this study, six grid-connected string inverters were characterized based on the Indian standard IS 16169:2019. This paper presents the real-time simulation results of grid loss protection in both single- and three-phase solar grid-connected inverters when connected to the utility. The study shows that the three-phase string inverters have lesser disconnection times in comparison with the single phase. With the increase in power capacity of string inverters, it is observed that irrespective of single or three phases, the disconnection time decreases.
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Engineering & Technology
Archieval Section
Not for loan 2022-1590
Total holds: 0

Anti-islanding protection plays a major role in grid-connected inverters which are based either on solar PV or other renewable energy resources when they are connected to the utility. In this study, six grid-connected string inverters were characterized based on the Indian standard IS 16169:2019. This paper presents the real-time simulation results of grid loss protection in both single- and three-phase solar grid-connected inverters when connected to the utility. The study shows that the three-phase string inverters have lesser disconnection times in comparison with the single phase. With the increase in power capacity of string inverters, it is observed that irrespective of single or three phases, the disconnection time decreases.

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha