Gamma scan data analysis using segmented FFT method to verify liquid maldistribution in distillation column of VDU

By: Walinjkar, Parag B.
Contributor(s): Yelgaonkar, V. N.
Publisher: New Delhi CSIR 2022Edition: Vol.60(2), Feb.Description: 101-104p.Subject(s): Humanities and Applied SciencesOnline resources: Click here In: Indian journal of pure & applied physics (IJPAP)Summary: Gamma scanning of the VDU was performed, to verify proper liquid distribution in the column section near Bed number 3. Gamma scanning was carried out in four chords and across two diameters 90 degrees apart. The recorded detector response (count-rate) data of each scan had analyzed using graphs, by co-relating it with column internals and also by comparing with each other. It was concluded that due to a faulty liquid distributor, the liquid is distributed unevenly in Bed number 3 of the column. This work has been published in 2016. From the graphs, it was not easy to derive the conclusions quickly. Also, the analysis done using graphs is qualitative in nature. The paper describes the study carried out to analyze the same data using the new segmented FFT method, without using graphs. In the study, the data was transformed into the frequency domain and then analyzed to interpret liquid maldistribution in the column. The results of the proposed segmented FFT analysis method are encouraging. It is concluded that the segmented FFT method of data analysis is better than the conventional chart-based method. Also, it is simple, fast, and quantitative.
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Engineering & Technology
Archieval Section
Not for loan 2022-1868
Total holds: 0

Gamma scanning of the VDU was performed, to verify proper liquid distribution in the column section near Bed number 3. Gamma scanning was carried out in four chords and across two diameters 90 degrees apart. The recorded detector response (count-rate) data of each scan had analyzed using graphs, by co-relating it with column internals and also by comparing with each other. It was concluded that due to a faulty liquid distributor, the liquid is distributed unevenly in Bed number 3 of the column. This work has been published in 2016. From the graphs, it was not easy to derive the conclusions quickly. Also, the analysis done using graphs is qualitative in nature. The paper describes the study carried out to analyze the same data using the new segmented FFT method, without using graphs. In the study, the data was transformed into the frequency domain and then analyzed to interpret liquid maldistribution in the column. The results of the proposed segmented FFT analysis method are encouraging. It is concluded that the segmented FFT method of data analysis is better than the conventional chart-based method. Also, it is simple, fast, and quantitative.

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha