Gamma passing rate – correlation with patient specific quality assurance devices using two photon energies in pelvic IMRT

By: Nigam, Jitendra.
Contributor(s): Piyush Kumar.
Publisher: New Delhi CSIR 2022Edition: Vol.60(9), Sep.Description: 773-782p.Subject(s): Humanities and Applied SciencesOnline resources: Click here In: Indian journal of pure & applied physics (IJPAP)Summary: The effect on Gamma Passing Rate is studied by changing the Photon Energy in the Patient Specific Quality Assurancein Pelvic IMRT using EPID and MatriXX keeping PSQA device at Isocenter. Dose verification of 62 patients, sufferingfrom pelvic malignancies and treated with Intensity modulated radiation therapy (IMRT), with EPID and MatriXX usinggamma criteria of 3%/3 mm, 3%/2 mm, 2%/3 mm, 2%/2 mm and investigated the effect on Gamma Passing Rate (%GP) bychanging beam energy from 6 MV to 10 MV. The results demonstrated that the behavior of gamma passing rate decreases ascriteria is changed from 3%/3 mm to strict criteria. The mean gamma passing rate for 6 MV beam were (%GP±StandardDeviation σ) 99.64±0.81, 99.45±1.08, 97.57±2.12, 96.17±2.63 using the criteria 3%/3 mm, 3%/2 mm, 2%/3 mm, 2%/2 mmrespectively in EPID. For MatriXX, the mean %GP were 96.69±4.11, 93.85±5.31, 88.17±10.63, 82.2±12.28 respectively.For 10 MV, the mean (%GP±Std. Dev) were 99.64±0.81, 99.45±1.08, 97.57±2.12, 96.17±2.63 for in EPID, 96.69±4.11,93.85±5.31, 88.17±10.63, 82.2±12.28 for MatriXX respectively. Difference between %GP for 6 MV and 10 MV beam were-0.01, -0.11, 1.08, 1.61 with gamma criteria of 3%/3 mm, 3%/2 mm, 2%/3 mm, 2%/2 in EPID. For MatriXX, differencebetween %GP for 6 MV and 10 MV beam were -0.40, -0.24, 0.96, 1.62 respectively. It can be concluded that applying morestrict gamma criteria results in low gamma passing rate. There is marked difference in Gamma Passing Rate (%GP) withchange in photon energy.
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Engineering & Technology
Archieval Section
Not for loan 2023-0666
Total holds: 0

The effect on Gamma Passing Rate is studied by changing the Photon Energy in the Patient Specific Quality Assurancein Pelvic IMRT using EPID and MatriXX keeping PSQA device at Isocenter. Dose verification of 62 patients, sufferingfrom pelvic malignancies and treated with Intensity modulated radiation therapy (IMRT), with EPID and MatriXX usinggamma criteria of 3%/3 mm, 3%/2 mm, 2%/3 mm, 2%/2 mm and investigated the effect on Gamma Passing Rate (%GP) bychanging beam energy from 6 MV to 10 MV. The results demonstrated that the behavior of gamma passing rate decreases ascriteria is changed from 3%/3 mm to strict criteria. The mean gamma passing rate for 6 MV beam were (%GP±StandardDeviation σ) 99.64±0.81, 99.45±1.08, 97.57±2.12, 96.17±2.63 using the criteria 3%/3 mm, 3%/2 mm, 2%/3 mm, 2%/2 mmrespectively in EPID. For MatriXX, the mean %GP were 96.69±4.11, 93.85±5.31, 88.17±10.63, 82.2±12.28 respectively.For 10 MV, the mean (%GP±Std. Dev) were 99.64±0.81, 99.45±1.08, 97.57±2.12, 96.17±2.63 for in EPID, 96.69±4.11,93.85±5.31, 88.17±10.63, 82.2±12.28 for MatriXX respectively. Difference between %GP for 6 MV and 10 MV beam were-0.01, -0.11, 1.08, 1.61 with gamma criteria of 3%/3 mm, 3%/2 mm, 2%/3 mm, 2%/2 in EPID. For MatriXX, differencebetween %GP for 6 MV and 10 MV beam were -0.40, -0.24, 0.96, 1.62 respectively. It can be concluded that applying morestrict gamma criteria results in low gamma passing rate. There is marked difference in Gamma Passing Rate (%GP) withchange in photon energy.

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha