Normal view MARC view ISBD view

HPLC Determination of n-methylethanolamine in diphenhydramine hydrochloride drug substance by pre-

By: Anerao, A.
Contributor(s): Dighe, V | Gupta, A.
Publisher: Mumbai Indian Drug Manufacture's Association - IDMA 2018Edition: Vol. 55 (10).Description: 56-62.Subject(s): PHARMACEUTICS | Derivatization validation In: Indian drugsSummary: N-Methylethanolamine is the side chain of the drug diphenhydramine hydrochloride. A sensitive high performance liquid chromatography method with pre-column derivatization was developed and validated for the determination of N-methylethanolamine impurity in diphenhydramine hydrochloride active pharmaceutical ingredient. HPLC method on column Cosmosil MS-II, C-18, 250 mm X 4.6 mm, particle size 5 μm with UV detector was used. The proposed method is specific, linear, accurate, rugged and precise. The calibration curves showed good linearity over the concentration range of 0.03 mg/g to 1.5 mg/g and the correlation coefficient was 0.999. Method had very low limit of detection (LOD) and limit of quantification (LOQ) as 0.01 mg/g and 0.03 mg/g, respectively, of the analyte. Accuracy was observed within 94.4% to 96.2%.
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Pharmacy
Archieval Section
Not for loan 2018008
Total holds: 0

N-Methylethanolamine is the side chain of the drug diphenhydramine hydrochloride. A sensitive high performance liquid chromatography method with pre-column derivatization was developed and validated for the determination of N-methylethanolamine impurity in diphenhydramine hydrochloride active pharmaceutical ingredient. HPLC method on column Cosmosil MS-II, C-18, 250 mm X 4.6 mm, particle size 5 μm with UV detector was used. The proposed method is specific, linear, accurate, rugged and precise. The calibration curves showed good linearity over the concentration range of 0.03 mg/g to 1.5 mg/g and the correlation coefficient was 0.999. Method had very low limit of detection (LOD) and limit of quantification (LOQ) as 0.01 mg/g and 0.03 mg/g, respectively, of the analyte. Accuracy was observed within 94.4% to 96.2%.

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha