Novel HPLC method for estimation of genotoxic impurity 3-acetamidobenzene 1, 2 dicarboxylic acid in a key starting material 3-acetamidopthalic anhydride of apremilast api

By: Shinde, P.
Contributor(s): Shirke, S | Dwivedi, R.
Publisher: Mumbai Indian Drug Manufacture's Association - IDMA 2018Edition: Vol. 55 (06) June.Description: 41-45.Subject(s): PHARMACEUTICS In: Indian drugsSummary: 3-Acetamidobenzene 1, 2 dicarboxylic acid is a potential genotoxic impurity which gets formed during synthesis of 3-Acetamidopthalic anhydride, a key starting material (KSM) for manufacturing of Apremilast API. During handling upon exposure to moisture, the anhydride ring of KSM 3-Acetamidopthalic anhydride opens to form acid. Hence Reverse phase HPLC method is not a feasible and robust option for estimation of this impurity. To overcome these problems a Normal phase HPLC method is developed and proposed in this research work. Immobilized Chiral pack IA column from Daicel is used for estimation. n-Hexane and isopropyl alcohol in 90:10 (v/v) ratio modified with 0.1% trifluroacetic acid is used as Mobile phase. Method is validated as per ICH guidelines. Limit of Detection (LOD) and Limit of Quantification (LOQ) are found to be 0.47 ppm (0.0047%) and 1.42 ppm (0.0142%), respectively. The method is linear over LOQ to 150%. Recovery is within limit (80-120%). Method is robust for parameters like mobile phase composition, flow rate, wavelength changes and column oven temperature.
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Pharmacy
Archieval Section
Not for loan 2018025
Total holds: 0

3-Acetamidobenzene 1, 2 dicarboxylic acid is a potential genotoxic impurity which gets formed during synthesis of 3-Acetamidopthalic anhydride, a key starting material (KSM) for manufacturing of Apremilast API. During handling upon exposure to moisture, the anhydride ring of KSM 3-Acetamidopthalic anhydride opens to form acid. Hence Reverse phase HPLC method is not a feasible and robust option for estimation of this impurity. To overcome these problems a Normal phase HPLC method is developed and proposed in this research work. Immobilized Chiral pack IA column from Daicel is used for estimation. n-Hexane and isopropyl alcohol in 90:10 (v/v) ratio modified with 0.1% trifluroacetic acid is used as Mobile phase. Method is validated as per ICH guidelines. Limit of Detection (LOD) and Limit of Quantification (LOQ) are found to be 0.47 ppm (0.0047%) and 1.42 ppm (0.0142%), respectively. The method is linear over LOQ to 150%. Recovery is within limit (80-120%). Method is robust for parameters like mobile phase composition, flow rate, wavelength changes and column oven temperature.

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha