Normal view MARC view ISBD view

PLC-Based Stator Water Cooling System for High-Capacity Generators in Power Plant

By: N. M., Ahnisiya.
Contributor(s): A, Dikshaya.
Publisher: Delhi Journals Pub 2018Edition: Vol, 4(01), Jan-June.Description: 34-41.Subject(s): Electrical EngineeringOnline resources: Click here In: International journal of electrical machines & drivesSummary: The power station generator will be a high-capacity machine. Because of the enormous current handling capacity, in terms of thousands of amperes—heat generation will be more. The minimum allowable time for a generator running without stator water cooling system (SWCS) is only 17 seconds. In case of any problem in SWCS, it will cause disturbance in power production and results in major revenue loss to the industry. Hence cooling of generators plays a vital role. Failure in cooling arrangement will result in tripping of generator from grid. SWCS using relays are now in practice, but it has to be manually monitored regularly. In order to overcome this problem, we propose PLC for stator cooling. Monitoring SWCS is efficient with programmable logic controller (PLC) as control platform. Control software for SWCS uses ladder programming supports. PLC is ready to render reliable solution through friendly software and will challenge any level of complications. PLC replaces conventional relays/timer-based old control system.
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Engineering & Technology
Archieval Section
Not for loan 2018081
Total holds: 0

The power station generator will be a high-capacity machine. Because of the enormous current handling capacity, in terms of thousands of amperes—heat generation will be more. The minimum allowable time for a generator running without stator water cooling system (SWCS) is only 17 seconds. In case of any problem in SWCS, it will cause disturbance in power production and results in major revenue loss to the industry. Hence cooling of generators plays a vital role. Failure in cooling arrangement will result in tripping of generator from grid. SWCS using relays are now in practice, but it has to be manually monitored regularly. In order to overcome this problem, we propose PLC for stator cooling. Monitoring SWCS is efficient with programmable logic controller (PLC) as control platform. Control software for SWCS uses ladder programming supports. PLC is ready to render reliable solution through friendly software and will challenge any level of complications. PLC replaces conventional relays/timer-based old control system.

There are no comments for this item.

Log in to your account to post a comment.
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha