Normal view MARC view ISBD view

Chemometrics assisted stability indication RP-HPLC method for the simulataneous determination of acetyl cysteine and ambroxol hydrochloride in bulk and dosage form

By: Potluri, H.
Publisher: Mumbai Indian Drug Manufacturers Association 2019Edition: Vol. 56(03), March.Description: 46-53p.Subject(s): DRUG STORE MANAGEMENTOnline resources: Click here In: Indian drugsSummary: A simple and precise stability indicating RP-HPLC method was developed for the simultaneous estimation of acetyl cysteine and ambroxol hydrochloride in bulk and dosage form. Experimental design based evaluation using a 23 full factorial design was applied to evaluate coefficient, ANOVA for the establishment of robustness nature of the method. Kromosil (250 mm x 4.6 mm, 5 μ) C18 column at 274 nm of UV detection was used. A composition of 0.1 % ortho phosphoric acid and acetonitrile in the ratio of 28:72 (V:V) was used as the mobile phase with a flow rate of 1.0 mL min-1. Linearity was established over the concentration range of 50-300 μg. mL-1 for acetyl cysteine and 7.5-45 μg mL-1 for ambroxol hydrochloride. The proposed method was validated and was successfully utilized for the quantitative analysis of tablet formulations containing acetyl cysteine and ambroxol hydrochloride.
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Pharmacy
Archieval Section
Not for loan 2018478
Total holds: 0

A simple and precise stability indicating RP-HPLC method was developed for the simultaneous estimation of acetyl cysteine and ambroxol hydrochloride in bulk and dosage form. Experimental design based evaluation using a 23 full factorial design was applied to evaluate coefficient, ANOVA for the establishment of robustness nature of the method. Kromosil (250 mm x 4.6 mm, 5 μ) C18 column at 274 nm of UV detection was used. A composition of 0.1 % ortho phosphoric acid and acetonitrile in the ratio of 28:72 (V:V) was used as the mobile phase with a flow rate of 1.0 mL min-1. Linearity was established over the concentration range of 50-300 μg. mL-1 for acetyl cysteine and 7.5-45 μg mL-1 for ambroxol hydrochloride. The proposed method was validated and was successfully utilized for the quantitative analysis of tablet formulations containing acetyl cysteine and ambroxol hydrochloride.

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha