Performance of steel fiber reinforced concrete columns exposed to high temperatures under different cooling conditions

By: Reddy, K. Ratna Tej.
Contributor(s): Rao, K. Srinivasa.
Publisher: Thane ACC LTD 2019Edition: Vol.93(08), August.Description: 32-42p.Subject(s): Civil EngineeringOnline resources: Click here In: Indian Concrete JournalSummary: This paper aims to present the study conducted on steel fiber reinforced concrete columns that were exposed to temperatures up to 800ºC and cooled by two methods. The study was carried out on 34 columns of length 1200 mm and cross section of 150 mm X 150 mm, out of which 17 were RC columns with steel fibers, while the remaining 17 were made of just reinforced concrete. The columns are heated at temperatures of 100, 200, 300, 400, 500, 600, 700 and 800ºC for a duration of 3 hours at each temperature, and later cooled by two methods, namely, natural air cooling and water quenching. The samples were tested for first crack load, ultimate load and toughness, and the results are discussed
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Engineering & Technology (PG)
Archieval Section
Not for loan 2019745
Total holds: 0

This paper aims to present the study conducted on steel fiber reinforced concrete columns that were exposed to temperatures up to 800ºC and cooled by two methods. The study was carried out on 34 columns of length 1200 mm and cross section of 150 mm X 150 mm, out of which 17 were RC columns with steel fibers, while the remaining 17 were made of just reinforced concrete. The columns are heated at temperatures of 100, 200, 300, 400, 500, 600, 700 and 800ºC for a duration of 3 hours at each temperature, and later cooled by two methods, namely, natural air cooling and water quenching. The samples were tested for first crack load, ultimate load and toughness, and the results are discussed

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha