Improvement of fire resistance of reinforced concrete columns by using diamond tie configuration

By: Buch, Shujaat H.
Contributor(s): Sharma, Umesh K.
Publisher: Thane ACC LTD 2019Edition: Vol93(08), August.Description: 51-56p.Subject(s): Civil EngineeringOnline resources: Click here In: Indian Concrete JournalSummary: As per the Indian codal guidelines, the ties in reinforced concrete columns are provided either as rectangular or circular depending on the shape of column. In addition to perimeter ties, single or multi-legged crossties are also provided for larger sections. At ambient temperatures, it has been observed that decrease in tie spacing is beneficial as it increases moment capacity of the section leading to better confinement. However, in case of fire the positive effects of decrease in tie spacing beyond 100 mm have not been observed. Considering that the transverse and circumferential cracks are observed in columns due to thermal gradients as known from literature review, the diamond tie configuration was adopted in reinforced concrete columns. Three reinforced concrete columns of full-scale size, 3.15 m each, (two control and other with diamond configuration) are loaded at service load with maximum expected load eccentricity. They are subjected to ISO-834 standard fire curve in a furnace. It is observed that there is an improvement in fire resistance by 150% for column with diamond configuration as compared to rectangular tie configuration with crossties. Further, it is observed that there was no appreciable variation in the amount of spalling for columns with diamond configuration. This indicated better confinement during fire for columns with diamond configuration. It also indicates that diamond configuration of ties reduces the effect of thermal gradient cracks in limiting the fire resistance of RC columns particularly at decreased tie spacing
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Engineering & Technology (PG)
Archieval Section
Not for loan 2019749
Total holds: 0

As per the Indian codal guidelines, the ties in reinforced concrete columns are provided either as rectangular or circular depending on the shape of column. In addition to perimeter ties, single or multi-legged crossties are also provided for larger sections. At ambient temperatures, it has been observed that decrease in tie spacing is beneficial as it increases moment capacity of the section leading to better confinement. However, in case of fire the positive effects of decrease in tie spacing beyond 100 mm have not been observed. Considering that the transverse and circumferential cracks are observed in columns due to thermal gradients as known from literature review, the diamond tie configuration was adopted in reinforced concrete columns. Three reinforced concrete columns of full-scale size, 3.15 m each, (two control and other with diamond configuration) are loaded at service load with maximum expected load eccentricity. They are subjected to ISO-834 standard fire curve in a furnace. It is observed that there is an improvement in fire resistance by 150% for column with diamond configuration as compared to rectangular tie configuration with crossties. Further, it is observed that there was no appreciable variation in the amount of spalling for columns with diamond configuration. This indicated better confinement during fire for columns with diamond configuration. It also indicates that diamond configuration of ties reduces the effect of thermal gradient cracks in limiting the fire resistance of RC columns particularly at decreased tie spacing

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha