Synchronizing Quality Analysis of HVAC-HVDC Parallal Tie-Line for Synchronization of Hydro, Thermal and Nuclear Power Grid

By: Sahu, Pankaj Kumar.
Publisher: New Delhi STM Journals 2018Edition: Vol.8(1), Jan-Apr.Description: 48-58p.Subject(s): Electrical EngineeringOnline resources: Click here In: Trends in electrical engineering (TEE)Summary: This research work prove the synchronizing quality of HVAC-HVDC parallel tie-line is different in Hydro, Thermal and Nuclear Power Grid. The synchronizing quality of HVAC-HVDC parallel tie-line is superior in Thermal Power Grid as compare to the Hydro & Nuclear Power Grid. This project work is also proves the synchronizing quality of HVAC-HVDC parallel tie-line is superior in Nuclear Power Grid as compare to the Hydro Power Grid. The synchronizing quality of HVAC-HVDC parallel tie-line in Hydro, Thermal & Nuclear Power Grid is judged by the settling time of frequency & tie-line power deviation of power grid in case of ∆PL6 = 0.01 p.u. load change in power grid-1. In this research work synchronization of Hydro, Thermal & Nuclear Power Grid is done by HVAC-HVDC parallel tie-line with traditional integral controller.
Tags from this library: No tags from this library for this title. Log in to add tags.
    average rating: 0.0 (0 votes)
Item type Current location Call number Status Date due Barcode Item holds
Articles Abstract Database Articles Abstract Database School of Engineering & Technology
Archieval Section
Not for loan 2020071
Total holds: 0

This research work prove the synchronizing quality of HVAC-HVDC parallel tie-line is different in Hydro, Thermal and Nuclear Power Grid. The synchronizing quality of HVAC-HVDC parallel tie-line is superior in Thermal Power Grid as compare to the Hydro & Nuclear Power Grid. This project work is also proves the synchronizing quality of HVAC-HVDC parallel tie-line is superior in Nuclear Power Grid as compare to the Hydro Power Grid. The synchronizing quality of HVAC-HVDC parallel tie-line in Hydro, Thermal & Nuclear Power Grid is judged by the settling time of frequency & tie-line power deviation of power grid in case of ∆PL6 = 0.01 p.u. load change in power grid-1. In this research work synchronization of Hydro, Thermal & Nuclear Power Grid is done by HVAC-HVDC parallel tie-line with traditional integral controller.

There are no comments for this item.

Log in to your account to post a comment.

Click on an image to view it in the image viewer

Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.

Powered by Koha