000 a
999 _c15910
_d15910
003 OSt
005 20220106114648.0
008 220106b xxu||||| |||| 00| 0 eng d
040 _aAIKTC-KRRC
_cAIKTC-KRRC
100 _915360
_aKhan, Hamid
245 _aIdentification and characterization of degradation products of valsartan by UPLC/Q-TOF-MS technique
250 _aVol.11(1), Jan-Mar
260 _aRaipur
_bAsian Pharma Press
_c2021
300 _a1-5p.
520 _aUPLC/Q-TOF-MS (Ultra-performance liquid chromatographic/quadrupole time-of-flight mass spectrometric) technique has been applied for identification and characterization of degradation products of Valsartan. For identification of drugs, the Q-TOF mass spectrometer was operated in negative ionization mode and quantification was done using the MS/MS transitions at m/z 434.50 to 255.50. The chromatographic separation was achieved on Acquity UPLCTM BEH C18 (100.0 × 2.1 mm, 1.7µm) column using isocratic mobile phase consisting of acetonitrile-2mM ammonium acetate (50:50, v/v) at a flow rate of 0.25 mL/min. Drug was degraded when treated with acid, alkali and oxidative stress conditions but found stable in photolytic condition. Degradation products were identified and possible degradation mechanisms were established.
650 0 _94639
_aPHARMACEUTICS
773 0 _x2231-5683
_tAsian journal of pharmaceutical research
_dRaipur Asian Pharma Press
856 _uhttps://asianjpr.com/AbstractView.aspx?PID=2021-11-1-1
_yClick here
942 _2ddc
_cAR