High performance liquid chromatographic- diode array detector method for simultaneous estimation of escitalopram oxalate and flupentixol dihydrochloride in combination (Record no. 10556)
[ view plain ]
                            
                            | 000 -LEADER | |
|---|---|
| fixed length control field | a | 
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | OSt | 
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20191216121800.0 | 
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 191216b xxu||||| |||| 00| 0 eng d | 
| 040 ## - CATALOGING SOURCE | |
| Original cataloging agency | AIKTC-KRRC | 
| Transcribing agency | AIKTC-KRRC | 
| 100 ## - MAIN ENTRY--PERSONAL NAME | |
| 9 (RLIN) | 11208 | 
| Author | Gawande, V. V. | 
| 245 ## - TITLE STATEMENT | |
| Title | High performance liquid chromatographic- diode array detector method for simultaneous estimation of escitalopram oxalate and flupentixol dihydrochloride in combination | 
| 250 ## - EDITION STATEMENT | |
| Volume, Issue number | Vol. 56 (08) | 
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
| Place of publication, distribution, etc. | Mumbai | 
| Name of publisher, distributor, etc. | Indian Drug Manufacture's Association - IDMA | 
| Year | 2019 | 
| 300 ## - PHYSICAL DESCRIPTION | |
| Pagination | 61-68p. | 
| 520 ## - SUMMARY, ETC. | |
| Summary, etc. | The proposed work involves High Performance Liquid Chromatographic – Diode Array Detector method for estimation of escitalopram oxalate and flupentixol dihydrochloride in combination. The analytes were resolved on Waters C18 Xterra column (50 × 4.6 mm id, particle size 3.5 μm) with mobile phase composition of water (containing 0.2 % triethylamine pH adjusted to 2.5 with orthophosphoric acid): acetonitrile: methanol (62:28:10 % v/v/v). The flow rate kept was 1.0 mL/min opting isocratic mode and eluents were tracked down at 230 nm. The retention times for both the drugs were 1.38±0.21 and 2.98±0.41, respectively. Standard addition method was employed for the analysis of flupentixol dihydrochloride. ICH guidelines were followed to validate the method. The method assured linearity in concentration range of 50-150 μg/mL and 2.5-7.5 μg/mL for ESC and FLU, respectively. The method assured high degree of precision and accuracy. The method was proved to be robust by assessing robustness parameters. | 
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| 9 (RLIN) | 4639 | 
| Topical term or geographic name entry element | PHARMACEUTICS | 
| 700 ## - ADDED ENTRY--PERSONAL NAME | |
| 9 (RLIN) | 11210 | 
| Co-Author | Chandewar, A. V. | 
| 773 0# - HOST ITEM ENTRY | |
| Place, publisher, and date of publication | Mumbai Indian Drug Manufactures Association | 
| Title | Indian drugs | 
| 856 ## - ELECTRONIC LOCATION AND ACCESS | |
| URL | https://www.indiandrugsonline.org/issuesarticle-details?id=OTY2 | 
| Link text | Click here | 
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Dewey Decimal Classification | 
| Koha item type | Articles Abstract Database | 
| Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Home library | Current library | Shelving location | Date acquired | Total Checkouts | Barcode | Date last seen | Price effective from | Koha item type | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dewey Decimal Classification | School of Pharmacy | School of Pharmacy | Archieval Section | 16/12/2019 | 2020486 | 16/12/2019 | 16/12/2019 | Articles Abstract Database | 
