High performance liquid chromatographic- diode array detector method for simultaneous estimation of escitalopram oxalate and flupentixol dihydrochloride in combination (Record no. 10556)

MARC details
000 -LEADER
fixed length control field a
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20191216121800.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 191216b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency AIKTC-KRRC
Transcribing agency AIKTC-KRRC
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 11208
Author Gawande, V. V.
245 ## - TITLE STATEMENT
Title High performance liquid chromatographic- diode array detector method for simultaneous estimation of escitalopram oxalate and flupentixol dihydrochloride in combination
250 ## - EDITION STATEMENT
Volume, Issue number Vol. 56 (08)
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Mumbai
Name of publisher, distributor, etc. Indian Drug Manufacture's Association - IDMA
Year 2019
300 ## - PHYSICAL DESCRIPTION
Pagination 61-68p.
520 ## - SUMMARY, ETC.
Summary, etc. The proposed work involves High Performance Liquid Chromatographic – Diode Array Detector method for estimation of escitalopram oxalate and flupentixol dihydrochloride in combination. The analytes were resolved on Waters C18 Xterra column (50 × 4.6 mm id, particle size 3.5 μm) with mobile phase composition of water (containing 0.2 % triethylamine pH adjusted to 2.5 with orthophosphoric acid): acetonitrile: methanol (62:28:10 % v/v/v). The flow rate kept was 1.0 mL/min opting isocratic mode and eluents were tracked down at 230 nm. The retention times for both the drugs were 1.38±0.21 and 2.98±0.41, respectively. Standard addition method was employed for the analysis of flupentixol dihydrochloride. ICH guidelines were followed to validate the method. The method assured linearity in concentration range of 50-150 μg/mL and 2.5-7.5 μg/mL for ESC and FLU, respectively. The method assured high degree of precision and accuracy. The method was proved to be robust by assessing robustness parameters.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 4639
Topical term or geographic name entry element PHARMACEUTICS
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 11210
Co-Author Chandewar, A. V.
773 0# - HOST ITEM ENTRY
Place, publisher, and date of publication Mumbai Indian Drug Manufactures Association
Title Indian drugs
856 ## - ELECTRONIC LOCATION AND ACCESS
URL https://www.indiandrugsonline.org/issuesarticle-details?id=OTY2
Link text Click here
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Articles Abstract Database
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Shelving location Date acquired Total Checkouts Barcode Date last seen Price effective from Koha item type
    Dewey Decimal Classification     School of Pharmacy School of Pharmacy Archieval Section 16/12/2019   2020486 16/12/2019 16/12/2019 Articles Abstract Database
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.