BAUR DAM BREACH ANALYSIS USING 2D HEC-RAS (Record no. 15249)

MARC details
000 -LEADER
fixed length control field a
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20210923122005.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 210923b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency AIKTC-KRRC
Transcribing agency AIKTC-KRRC
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 14321
Author Ramola, Meenakshi
245 ## - TITLE STATEMENT
Title BAUR DAM BREACH ANALYSIS USING 2D HEC-RAS
250 ## - EDITION STATEMENT
Volume, Issue number Vol.39(4), Oct
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Roorkee
Name of publisher, distributor, etc. Indian Water Resources Society
Year 2019
300 ## - PHYSICAL DESCRIPTION
Pagination 1-5p.
520 ## - SUMMARY, ETC.
Summary, etc. Dam is a very essential part of our society. It provides power supply, irrigation water, tourism, navigation and many other benefits. Dam structure is very <br/>crucial and lack of strategy, maintenance, structure design can cause high level of flood devastation to the adjacent area. It affects at high level interms of loss <br/>e, loss of economy, environment degradation etc. Dam breach process may be instantaneous or gradual, depend<br/>paper hypothetical breach of earthen dam has been analysed by using HEC-RAS, which is a computer program and used for dam breach modelling. <br/>Methodology adopted during modelling is summarised in this paper. Dam breach analysis is important, it provides detail knowle<br/>e elevation values and also about inundated areas by using inundation maps. These maps are useful for<br/>administration and other stakeholders at the time of emergency, so that local people can be saved by providing emergency warn<br/>show that overtopping failure causes more flood with respect to piping failure in earthen dam, however the difference is meag<br/>study based on limited data of Baur dam (Uttarakhand) analysed using HEC-RAS modelling breach guidelines. The results of HEC<br/>worst scenario is pool reservoir level with overtopping failure pattern of Baur dam.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 4621
Topical term or geographic name entry element Civil Engineering
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 14322
Co-Author Prasad, Jyothi
773 0# - HOST ITEM ENTRY
Place, publisher, and date of publication Roorkee Indian Institute of Technology Roorkee
Title Journal of indian water resource society
International Standard Serial Number 0970-6984
856 ## - ELECTRONIC LOCATION AND ACCESS
URL http://iwrs.org.in/journal/oct2019/1oct.pdf
Link text Click here
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Articles Abstract Database
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Shelving location Date acquired Total Checkouts Barcode Date last seen Price effective from Koha item type
    Dewey Decimal Classification     School of Engineering & Technology (PG) School of Engineering & Technology (PG) Archieval Section 23/09/2021   2021-2022126 23/09/2021 23/09/2021 Articles Abstract Database