Constructability and Detailing of RC Coupling Beams (Record no. 15855)

MARC details
000 -LEADER
fixed length control field a
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20211230155425.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 211230b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency AIKTC-KRRC
Transcribing agency AIKTC-KRRC
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 6372
Author Subramanian, N.
245 ## - TITLE STATEMENT
Title Constructability and Detailing of RC Coupling Beams
250 ## - EDITION STATEMENT
Volume, Issue number Vol.95(8), August
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Thane
Name of publisher, distributor, etc. ACC LTD
Year 2021
300 ## - PHYSICAL DESCRIPTION
Pagination 45-55p.
520 ## - SUMMARY, ETC.
Summary, etc. Coupled shear walls of multi-storey reinforced concrete buildings have been used in the past in earthquake zones. However, conventionally reinforced concrete coupling beams with length to depth ratio less than 4.0 were found to have deficient performance, especially during earthquake loading. Based on extensive experimental research, researchers have found that detailing of coupling beams using inclined reinforcement are more effective and perform better with adequate ductility. But such a detailing resulted in two constructability problems: (1) Two groups of diagonal reinforcement have to be provided with closely spaced ties, and (2) These diagonal bars have to be anchored in the adjacent walls, with 1.5 times the development length. ACI 318 (2019) suggested an alternate detailing option, where transverse reinforcement is placed around the beam cross section to provide confinement and suppress buckling, and no transverse reinforcement directly around the diagonal bar bundles. Such an option should also be provided in IS: 13920 (2016) for easy constructability. Various other alternate reinforcement details involving diagonal reinforcement, which are bent at the beam ends inside the coupling beam have also been proposed. The use of HPFRC with low volume fractions of fibres, can not only reduce the amount of steel used, but also reduce labour by simplifying the placement of reinforcement and accelerate construction schedule of these coupling beams.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 4621
Topical term or geographic name entry element Civil Engineering
773 0# - HOST ITEM ENTRY
Title Indian Concrete Journal - ICJ
Place, publisher, and date of publication Thane ACC Limited
856 ## - ELECTRONIC LOCATION AND ACCESS
URL https://www.icjonline.com/editionabstract_detail/082021
Link text Click here
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Articles Abstract Database
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Shelving location Date acquired Total Checkouts Barcode Date last seen Price effective from Koha item type
    Dewey Decimal Classification     School of Engineering & Technology (PG) School of Engineering & Technology (PG) Archieval Section 30/12/2021   2021-2022672 30/12/2021 30/12/2021 Articles Abstract Database
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.