Water Conservation: An Innovative Approach towards Minimization of Blow-Down for Recirculating Cooling Water System (Record no. 17802)

MARC details
000 -LEADER
fixed length control field a
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20221015163150.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 221015b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency AIKTC-KRRC
Transcribing agency AIKTC-KRRC
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 18388
Author Chatterjee, P. K.
245 ## - TITLE STATEMENT
Title Water Conservation: An Innovative Approach towards Minimization of Blow-Down for Recirculating Cooling Water System
250 ## - EDITION STATEMENT
Volume, Issue number Vol, 103(2), April
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Kolkatta
Name of publisher, distributor, etc. Springer
Year 2022
300 ## - PHYSICAL DESCRIPTION
Pagination 239–248p
520 ## - SUMMARY, ETC.
Summary, etc. Water is the preferred cooling media in numerous industrial applications. Recirculating cooling water system with cooling tower is a common setup in thermal power plants, iron & steel plant, petroleum refinery and other industries. Cooling Tower working in the principle of evaporative cooling allows a small fraction of circulating water to pass into the vapour phase dissipating the thermal load from water as latent heat. As water molecule evaporates, concentration of dissolved species in circulating water build-up with consequence of deposition of scales like CaCO3, CaSO4 inside heat-exchanging equipment. Scaling is the biggest danger for heat transfer process. The preventive mechanism is to discharge a portion of cooling water termed as “blow-down” along with dosing of scale inhibiting chemical in the circulating water. The blow-down constitutes a major portion of the total makeup water demand of the cooling water circuit. The current article demonstrates an innovative scheme of ion-exchange based side-stream softening treatment (3ST) for a small fraction (~ 1%) of circulating water is capable of reducing blow-down quantity significantly with simultaneous reduction of scale-formation possibility. While reduction in blow-down helps conservation of water, additional benefits are lower scale problems and better equipment (Heat exchangers, pipes) health, and a possible reduction in dosing of scale inhibiting chemical. From theoretical viewpoint with 3ST technique, a close approach to “zero blow-down” is possible with negligible quantity of forced blow-down in the form of drift loss.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 4626
Topical term or geographic name entry element Mechanical Engineering
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 18389
Co-Author Rahman, M
773 0# - HOST ITEM ENTRY
Title Journal of the institution of engineers (India): Series C
International Standard Serial Number 2250-0545
Place, publisher, and date of publication Kolkata Institution of Engineers (India)
856 ## - ELECTRONIC LOCATION AND ACCESS
URL https://link.springer.com/article/10.1007/s40032-021-00768-7
Link text Click here
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Articles Abstract Database
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Shelving location Date acquired Total Checkouts Barcode Date last seen Price effective from Koha item type
    Dewey Decimal Classification     School of Engineering & Technology School of Engineering & Technology Archieval Section 15/10/2022   2022-1855 15/10/2022 15/10/2022 Articles Abstract Database
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.