Performance assessment of calcium nitrite based corrosion inhibiting admixture in reinforced concrete (Record no. 18053)

MARC details
000 -LEADER
fixed length control field a
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20221103120758.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 221103b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency AIKTC-KRRC
Transcribing agency AIKTC-KRRC
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 9673
Author Pattanaik, Suresh Chandra
245 ## - TITLE STATEMENT
Title Performance assessment of calcium nitrite based corrosion inhibiting admixture in reinforced concrete
250 ## - EDITION STATEMENT
Volume, Issue number Vol96(4), Apr
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Thana
Name of publisher, distributor, etc. ACC LTD
Year 2022
300 ## - PHYSICAL DESCRIPTION
Pagination 28-39p.
520 ## - SUMMARY, ETC.
Summary, etc. The durability of the reinforced concrete structures in the marine environment can be achieved by adding corrosion inhibitors in the concrete mix. Performances of concrete specimens were evaluated for control and having corrosion inhibiting admixtures of calcium nitrite at 30 % concentration of the active ingredient without induced corrosion environment. The various tests performed were concrete resistivity, rapid chloride permeability test (RCPT), compressive strength, and microscopic analysis of concrete specimens at normal exposure condition. The reinforced concrete specimens were prepared of M30 grade concrete with and without calcium nitrite based chemical admixture of varying dosages of 1 and 2 % by weight of cement. The corrosion probability was found low and negligible in concrete specimens with corrosion inhibiting admixtures as compared to control samples when tested for electrical resistivity. There was also marginal improvement in the 28-days compressive strength of samples having corrosion inhibiting admixture as compared to control samples. Alternatively, no such appreciable improvement was noticed in any samples made with corrosion inhibiting admixture for corrosion resistance while tested by RCPT. Thus, the RCPT result may mislead the performance of inhibiting admixtures to protect the corrosion in reinforced concrete. Moreover, the concrete resistivity test reveals the effectiveness of inhibiting admixture in corrosion prevention of reinforced concrete. Further, the microscopic study by petrographic examination disclosed that samples made with corrosion inhibiting admixture helped to reduce shrinkage cracks, reduces air voids and strong bond between aggregate-cement paste as compared to control sample.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 4621
Topical term or geographic name entry element Civil Engineering
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 14127
Co-Author Patro, Sanjaya Kumar
773 0# - HOST ITEM ENTRY
Title Indian Concrete Journal - ICJ
International Standard Serial Number 0019-4565
Place, publisher, and date of publication Thane ACC Limited
856 ## - ELECTRONIC LOCATION AND ACCESS
URL https://www.icjonline.com/editionabstract_detail/042022
Link text Click here
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Articles Abstract Database
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Shelving location Date acquired Total Checkouts Barcode Date last seen Price effective from Koha item type
    Dewey Decimal Classification     School of Engineering & Technology (PG) School of Engineering & Technology (PG) Archieval Section 03/11/2022   2022-1991 03/11/2022 03/11/2022 Articles Abstract Database
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.