Performance analysis of three-phase grid-connected solar photovoltaic system with dynamic grid support system. (Record no. 19146)

MARC details
000 -LEADER
fixed length control field a
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20230406090806.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 230406b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency AIKTC-KRRC
Transcribing agency AIKTC-KRRC
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 20426
Author Vegad, Sagar N.
245 ## - TITLE STATEMENT
Title Performance analysis of three-phase grid-connected solar photovoltaic system with dynamic grid support system.
250 ## - EDITION STATEMENT
Volume, Issue number Vol15(4), Oct
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Telangana
Name of publisher, distributor, etc. IUP Publications
Year 2022
300 ## - PHYSICAL DESCRIPTION
Pagination 55-69p.
520 ## - SUMMARY, ETC.
Summary, etc. Global energy needs are growing continuously, and there is now more focus on renewable energy sources. Solar Photovoltaic (PV) and wind have the major contribution among utility-level renewable energy sources. In India, till now gridconnected solar PV systems do not follow any specialized controls for grid support during disturbance and they isolate the solar PV system immediately with the help of anti-islanding technique. The paper presents a synchronous reference frame-based current control technique for solar PV inverters with low voltage ride-through control. A detailed performance analysis of grid-connected solar PV systems with and without low voltage ride-through control for various types of grid faults has been carried out. Various parameters like active and reactive power injection, circuit breaker opening time, dc-link voltage magnitude and voltage magnitude at the Point of Common Coupling (PCC) are recorded for symmetrical and unsymmetrical faults.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 4623
Topical term or geographic name entry element Electrical Engineering
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 20427
Co-Author Iyer, J. R.
773 0# - HOST ITEM ENTRY
Place, publisher, and date of publication Hyderabad IUP Publications
Title IUP journal of electrical and electronics engineering
International Standard Serial Number 0974-1704
856 ## - ELECTRONIC LOCATION AND ACCESS
URL https://web.p.ebscohost.com/abstract?site=ehost&scope=site&jrnl=09741704&AN=160877730&h=jKOh0jYh6Amck1DhXyYREc5IpDHFtC0Wu%2fZseVur6LgAbtBn6qq2Wy%2b81loXhtldM3NYNUt6TAUZPHLrJrb7Cw%3d%3d&crl=c&resultLocal=ErrCrlNoResults&resultNs=Ehost&crlhashurl=login.aspx%3fdirect%3dtrue%26profile%3dehost%26scope%3dsite%26authtype%3dcrawler%26jrnl%3d09741704%26AN%3d160877730
Link text Click here
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Articles Abstract Database
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Shelving location Date acquired Total Checkouts Barcode Date last seen Price effective from Koha item type
    Dewey Decimal Classification     School of Engineering & Technology School of Engineering & Technology Archieval Section 06/04/2023   2023-0630 06/04/2023 06/04/2023 Articles Abstract Database
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.