Performance analysis of three-phase grid-connected solar photovoltaic system with dynamic grid support system. (Record no. 19146)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | a |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | OSt |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20230406090806.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 230406b xxu||||| |||| 00| 0 eng d |
| 040 ## - CATALOGING SOURCE | |
| Original cataloging agency | AIKTC-KRRC |
| Transcribing agency | AIKTC-KRRC |
| 100 ## - MAIN ENTRY--PERSONAL NAME | |
| 9 (RLIN) | 20426 |
| Author | Vegad, Sagar N. |
| 245 ## - TITLE STATEMENT | |
| Title | Performance analysis of three-phase grid-connected solar photovoltaic system with dynamic grid support system. |
| 250 ## - EDITION STATEMENT | |
| Volume, Issue number | Vol15(4), Oct |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
| Place of publication, distribution, etc. | Telangana |
| Name of publisher, distributor, etc. | IUP Publications |
| Year | 2022 |
| 300 ## - PHYSICAL DESCRIPTION | |
| Pagination | 55-69p. |
| 520 ## - SUMMARY, ETC. | |
| Summary, etc. | Global energy needs are growing continuously, and there is now more focus on renewable energy sources. Solar Photovoltaic (PV) and wind have the major contribution among utility-level renewable energy sources. In India, till now gridconnected solar PV systems do not follow any specialized controls for grid support during disturbance and they isolate the solar PV system immediately with the help of anti-islanding technique. The paper presents a synchronous reference frame-based current control technique for solar PV inverters with low voltage ride-through control. A detailed performance analysis of grid-connected solar PV systems with and without low voltage ride-through control for various types of grid faults has been carried out. Various parameters like active and reactive power injection, circuit breaker opening time, dc-link voltage magnitude and voltage magnitude at the Point of Common Coupling (PCC) are recorded for symmetrical and unsymmetrical faults. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| 9 (RLIN) | 4623 |
| Topical term or geographic name entry element | Electrical Engineering |
| 700 ## - ADDED ENTRY--PERSONAL NAME | |
| 9 (RLIN) | 20427 |
| Co-Author | Iyer, J. R. |
| 773 0# - HOST ITEM ENTRY | |
| Place, publisher, and date of publication | Hyderabad IUP Publications |
| Title | IUP journal of electrical and electronics engineering |
| International Standard Serial Number | 0974-1704 |
| 856 ## - ELECTRONIC LOCATION AND ACCESS | |
| URL | https://web.p.ebscohost.com/abstract?site=ehost&scope=site&jrnl=09741704&AN=160877730&h=jKOh0jYh6Amck1DhXyYREc5IpDHFtC0Wu%2fZseVur6LgAbtBn6qq2Wy%2b81loXhtldM3NYNUt6TAUZPHLrJrb7Cw%3d%3d&crl=c&resultLocal=ErrCrlNoResults&resultNs=Ehost&crlhashurl=login.aspx%3fdirect%3dtrue%26profile%3dehost%26scope%3dsite%26authtype%3dcrawler%26jrnl%3d09741704%26AN%3d160877730 |
| Link text | Click here |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Dewey Decimal Classification |
| Koha item type | Articles Abstract Database |
| Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Home library | Current library | Shelving location | Date acquired | Total Checkouts | Barcode | Date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dewey Decimal Classification | School of Engineering & Technology | School of Engineering & Technology | Archieval Section | 06/04/2023 | 2023-0630 | 06/04/2023 | 06/04/2023 | Articles Abstract Database |