Gamma passing rate – correlation with patient specific quality assurance devices using two photon energies in pelvic IMRT (Record no. 19188)

MARC details
000 -LEADER
fixed length control field a
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20230411103550.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 230411b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency AIKTC-KRRC
Transcribing agency AIKTC-KRRC
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 20492
Author Nigam, Jitendra
245 ## - TITLE STATEMENT
Title Gamma passing rate – correlation with patient specific quality assurance devices using two photon energies in pelvic IMRT
250 ## - EDITION STATEMENT
Volume, Issue number Vol.60(9), Sep
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. New Delhi
Name of publisher, distributor, etc. CSIR
Year 2022
300 ## - PHYSICAL DESCRIPTION
Pagination 773-782p.
520 ## - SUMMARY, ETC.
Summary, etc. The effect on Gamma Passing Rate is studied by changing the Photon Energy in the Patient Specific Quality Assurancein Pelvic IMRT using EPID and MatriXX keeping PSQA device at Isocenter. Dose verification of 62 patients, sufferingfrom pelvic malignancies and treated with Intensity modulated radiation therapy (IMRT), with EPID and MatriXX usinggamma criteria of 3%/3 mm, 3%/2 mm, 2%/3 mm, 2%/2 mm and investigated the effect on Gamma Passing Rate (%GP) bychanging beam energy from 6 MV to 10 MV. The results demonstrated that the behavior of gamma passing rate decreases ascriteria is changed from 3%/3 mm to strict criteria. The mean gamma passing rate for 6 MV beam were (%GP±StandardDeviation σ) 99.64±0.81, 99.45±1.08, 97.57±2.12, 96.17±2.63 using the criteria 3%/3 mm, 3%/2 mm, 2%/3 mm, 2%/2 mmrespectively in EPID. For MatriXX, the mean %GP were 96.69±4.11, 93.85±5.31, 88.17±10.63, 82.2±12.28 respectively.For 10 MV, the mean (%GP±Std. Dev) were 99.64±0.81, 99.45±1.08, 97.57±2.12, 96.17±2.63 for in EPID, 96.69±4.11,93.85±5.31, 88.17±10.63, 82.2±12.28 for MatriXX respectively. Difference between %GP for 6 MV and 10 MV beam were-0.01, -0.11, 1.08, 1.61 with gamma criteria of 3%/3 mm, 3%/2 mm, 2%/3 mm, 2%/2 in EPID. For MatriXX, differencebetween %GP for 6 MV and 10 MV beam were -0.40, -0.24, 0.96, 1.62 respectively. It can be concluded that applying morestrict gamma criteria results in low gamma passing rate. There is marked difference in Gamma Passing Rate (%GP) withchange in photon energy.<br/>
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 4642
Topical term or geographic name entry element Humanities and Applied Sciences
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 14967
Co-Author Piyush Kumar
773 0# - HOST ITEM ENTRY
Title Indian journal of pure & applied physics (IJPAP)
Place, publisher, and date of publication New Delhi CSIR-NISCAIR
International Standard Serial Number 0019-5596
856 ## - ELECTRONIC LOCATION AND ACCESS
URL http://op.niscair.res.in/index.php/IJPAP/article/view/55453
Link text Click here
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Articles Abstract Database
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Shelving location Date acquired Total Checkouts Barcode Date last seen Price effective from Koha item type
    Dewey Decimal Classification     School of Engineering & Technology School of Engineering & Technology Archieval Section 11/04/2023   2023-0666 11/04/2023 11/04/2023 Articles Abstract Database
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.