Formwork removal time for concrete members using nominal mixes at different temperatures (Record no. 21858)

MARC details
000 -LEADER
fixed length control field a
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20241209101816.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 241209b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency AIKTC-KRRC
Transcribing agency AIKTC-KRRC
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 24703
Author Siddharth Shankar
245 ## - TITLE STATEMENT
Title Formwork removal time for concrete members using nominal mixes at different temperatures
250 ## - EDITION STATEMENT
Volume, Issue number Vol.98(4), Apr
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Thane
Name of publisher, distributor, etc. ACC LTD
Year 2024
300 ## - PHYSICAL DESCRIPTION
Pagination 43-55p.
520 ## - SUMMARY, ETC.
Summary, etc. A critical factor in the construction of reinforced cement concrete (RCC) structures is the timing of the safe removal of formwork. This time can be forecast using the maturity of concrete techniques and principles. Numerous academic publications suggest that formwork should be removed from the flexural members of RCC structures when concrete achieves at least 70 % of design strength. Early formwork removal might result in significant deformations or even failure. Nevertheless, delaying removal can cause construction delays that impact the profitability of the construction company and the use of the facility by the owner. Various countries’ codes, guidelines, and standards suggest stripping-time periods of different elements of RCC structures from twelve hours to thirty days. However, according to experiments conducted by authors, formwork for vertical concrete members must be stripped between 6 hours and 5.5 days, depending on the types of cement used and temperature ranges of 0°C to 45°C. Depending on the grade of the cement used and if the surrounding temperature is 45°C or 0°C, the time required to remove horizontal formwork ranges from 2.6 days to 124.4 days. Care must be taken when removing the formwork to prevent overstressing and damaging the concrete, especially when the ambient temperature is below 15°C. This is because many standard codes of practice are silent on the stripping time when the temperature is below 15°C. According to laboratory results conducted in this study at IIT Delhi, nominal mix cement concrete must have a compressive strength greater than 3.50 MPa to remove the vertical formwork in concrete made with ordinary Portland cement (OPC) and 3.25 MPa for Portland Pozzolana Cement (PPC).
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 4690
Topical term or geographic name entry element Construction Engineering and Management (CEM)
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 22607
Co-Author Jha, Kumar Neeraj
773 0# - HOST ITEM ENTRY
Title Indian Concrete Journal - ICJ
Place, publisher, and date of publication Thane ACC Limited
International Standard Serial Number 0019-4565
856 ## - ELECTRONIC LOCATION AND ACCESS
URL https://www.icjonline.com/editionabstract_detail/042024
Link text Click here
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Articles Abstract Database
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Shelving location Date acquired Total Checkouts Barcode Date last seen Price effective from Koha item type
    Dewey Decimal Classification     School of Engineering & Technology (PG) School of Engineering & Technology (PG) Archieval Section 09/12/2024   2024-1495 09/12/2024 09/12/2024 Articles Abstract Database
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.