Chemo metric assisted method development for the estimation of paracetamol, etoricoxib and thiocolchicoside in combined formulation (Record no. 22102)

MARC details
000 -LEADER
fixed length control field a
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250109160235.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 250109b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency AIKTC-KRRC
Transcribing agency AIKTC-KRRC
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 25053
Author Uparwad, Shital D.
245 ## - TITLE STATEMENT
Title Chemo metric assisted method development for the estimation of paracetamol, etoricoxib and thiocolchicoside in combined formulation
250 ## - EDITION STATEMENT
Volume, Issue number Vol.14(3), Jul-Sep
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Raipur
Name of publisher, distributor, etc. Asian Pharma Press
Year 2024
300 ## - PHYSICAL DESCRIPTION
Pagination 135-141p.
520 ## - SUMMARY, ETC.
Summary, etc. Chemometric based analytical method was developed for the estimation of Paracetamol (PCM), Etoricoxib (ECB) and Thiocolchicoside (TCS) by UV-VIS spectrophotometry. Spectroscopic technique, a simple, rapid, precise and accurate process for amount estimation is still in great use for analyst. For estimation of these drugs, solvent alcohol 90% was utilised and 248.5nm, 287nm and 380.5nm were the wavelength of absorbance measurement for PCM, ECB and TCS respectively. Effect of input variables on spectrum characteristics were studied for selection of critical parameters and developed method was validated as per ICH Q 2 R1 regulatory guidelines. Linearity of all these three drugs was ascertained over the conc range 1-14µg/ml for PCM and 1-24 µg/ml for both ECB and TCS. The accuracy of assay was found 102.66% for PCM, 98.56% for ECB and 98.02 % for TCS; and the precision study was shown acceptable data as %RSD data varied from 0.5382 to 1.6227 for PCM, from 0.4280 to 1.0521 for ECB and from 0.1438 to 0.8553 for TCS. The developed method is rigid, robust and efficient for the estimation of PCM, ECB and TCS from the combined composition of dosage form.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 4639
Topical term or geographic name entry element PHARMACEUTICS
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 25054
Co-Author Khapne, Sonali M.
773 0# - HOST ITEM ENTRY
International Standard Serial Number 2231-5667
Title Asian journal of pharmaceutical analysis
Place, publisher, and date of publication Raipur A & V Publications
856 ## - ELECTRONIC LOCATION AND ACCESS
URL https://ajpaonline.com/AbstractView.aspx?PID=2024-14-3-5
Link text Click here
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Articles Abstract Database
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Shelving location Date acquired Total Checkouts Barcode Date last seen Price effective from Koha item type
    Dewey Decimal Classification     School of Pharmacy School of Pharmacy Archieval Section 09/01/2025   2025-0018 09/01/2025 09/01/2025 Articles Abstract Database
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.