Thermal analysis of tube-in-tube type heat exchanger with augmentation technique using wilson plot and modified wilson plot methods (Record no. 23135)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | a |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | OSt |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20250721114841.0 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 250721b xxu||||| |||| 00| 0 eng d |
| 040 ## - CATALOGING SOURCE | |
| Original cataloging agency | AIKTC-KRRC |
| Transcribing agency | AIKTC-KRRC |
| 100 ## - MAIN ENTRY--PERSONAL NAME | |
| 9 (RLIN) | 26796 |
| Author | Kamble, Gautam S. |
| 245 ## - TITLE STATEMENT | |
| Title | Thermal analysis of tube-in-tube type heat exchanger with augmentation technique using wilson plot and modified wilson plot methods |
| 250 ## - EDITION STATEMENT | |
| Volume, Issue number | Vol.17(1), Feb |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
| Place of publication, distribution, etc. | Hyderabad |
| Name of publisher, distributor, etc. | IUP Publications |
| Year | 2024 |
| 300 ## - PHYSICAL DESCRIPTION | |
| Pagination | 7-23p. |
| 520 ## - SUMMARY, ETC. | |
| Summary, etc. | The paper explores the application of Wilson plot method, and its modifications, as an alternative approach for determining convective heat transfer coefficients in heat exchangers with complex geometries. For achieving the delicate balance, one needs to introduce heat transfer augmentation techniques in devices, which results in intricate geometries of heat exchanger. For such geometries of heat exchanger, correlations are not available to estimate convective heat transfer coefficients. The Wilson plot method provides a robust tool for deriving correlation equations based on experimental data. The paper discusses the implementation of the Wilson plot and modified Wilson plot methods to establish correlations for tube-in-tube type heat exchangers with wire mesh inserts, and results are obtained for both methods. It is found that modified Wilson plot method provides correlation with great accuracy in the range of 94 to 97%. Furthermore, the paper presents the development of a computational tool using VB.net, designed to facilitate the iterative calculations required for Wilson plot methods. The paper also describes a roadmap for the proficient application of Wilson plot method and its modification in heat exchanger analysis. |
| 650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| 9 (RLIN) | 4626 |
| Topical term or geographic name entry element | Mechanical Engineering |
| 700 ## - ADDED ENTRY--PERSONAL NAME | |
| 9 (RLIN) | 26797 |
| Co-Author | Shingate, Samruddhi V. |
| 773 0# - HOST ITEM ENTRY | |
| Place, publisher, and date of publication | Hyderabad IUP Publications |
| Title | IUP journal of mechanical engineering |
| International Standard Serial Number | 0974-6536 |
| 856 ## - ELECTRONIC LOCATION AND ACCESS | |
| URL | https://iupindia.in/ViewArticleDetails.asp?ArticleID=132 |
| Link text | Click here |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | Dewey Decimal Classification |
| Koha item type | Articles Abstract Database |
| Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Home library | Current library | Shelving location | Date acquired | Total Checkouts | Barcode | Date last seen | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dewey Decimal Classification | School of Engineering & Technology | School of Engineering & Technology | Archieval Section | 21/07/2025 | 2025-1070 | 21/07/2025 | 21/07/2025 | Articles Abstract Database |