Simple RP-HPLC method development and verification of the dissolution of bromelain-a complex mixture of proteolytic enzymes, in delayed-release tablets (Record no. 23425)

MARC details
000 -LEADER
fixed length control field a
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20250918120710.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 250918b xxu||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency AIKTC-KRRC
Transcribing agency AIKTC-KRRC
100 ## - MAIN ENTRY--PERSONAL NAME
9 (RLIN) 27219
Author Reddy, Bembadi Mukund
245 ## - TITLE STATEMENT
Title Simple RP-HPLC method development and verification of the dissolution of bromelain-a complex mixture of proteolytic enzymes, in delayed-release tablets
250 ## - EDITION STATEMENT
Volume, Issue number Vol.16(1)
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Bhopal
Name of publisher, distributor, etc. Innovare Academic Sciences Pvt Ltd
Year 2024
300 ## - PHYSICAL DESCRIPTION
Pagination 37-44p.
520 ## - SUMMARY, ETC.
Summary, etc. Objective: To develop a simple, accurate, precise and linear Reverse Phase High-Performance Liquid Chromatographic (RP-HPLC) method and verify for the quantitative estimation (Dissolution) of Bromelain in delayed-release tablets.<br/><br/>Methods: The optimized RP-HPLC method for both acid and buffer stage dissolutions of delayed-release tablets uses Zorbax 300 SB-C8 column (150 mm X 4.6 mm; 3.5μ), a mobile phase-A of 0.1% trifluoroacetic acid in water and a mobile phase-B of 0.1% Trifluoroacetic acid in Acetonitrile in the gradient proportion, flow rate of 1.0 ml/min, injection volume of 25 µl, detection wavelength of 280 nm using a UV/PDA detector, column temperature of 40 °C, sample tray/compartment temperature of 5 °C and a run time of 20 min.<br/><br/>Results: The developed method gave Bromelain eluting at about 6 min. Bromelain exhibited linearity in the range 53.4-800.6 μg/ml (r2=0.99992). The precision is exemplified by relative standard deviation of 1.3 and 2.3% for acid and buffer stages, respectively. Percentage recovery of the drug was found to be between 90.0 and 110.0 during accuracy studies.<br/><br/>Conclusion: A simple, accurate, precise, and linear RP-HPLC method was developed and verified for the quantitative estimation (Dissolution) of Bromelain in tablets and hence this method can be explored for the analysis of Bromelain in tablets in various pharmaceutical industries.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
9 (RLIN) 4639
Topical term or geographic name entry element PHARMACEUTICS
700 ## - ADDED ENTRY--PERSONAL NAME
9 (RLIN) 27220
Co-Author Reddy, Bheemi Reddy Ashok
773 0# - HOST ITEM ENTRY
International Standard Serial Number 2656-0097
Title International journal of pharmacy and pharmaceutical science
Place, publisher, and date of publication Bhopal Innovare Academic Sciences Pvt Ltd
856 ## - ELECTRONIC LOCATION AND ACCESS
URL https://journals.innovareacademics.in/index.php/ijpps/article/view/49569
Link text Click here
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme Dewey Decimal Classification
Koha item type Articles Abstract Database
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Shelving location Date acquired Total Checkouts Barcode Date last seen Price effective from Koha item type
    Dewey Decimal Classification     School of Pharmacy School of Pharmacy Archieval Section 18/09/2025   2025-1452 18/09/2025 18/09/2025 Articles Abstract Database
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.