EFFECT OF SOLVENTS IN CHROMATOGRAPHIC DETERMINATION OF SILDENAFIL CITRATE IN MARKETED FORMULATION

By: Contributor(s): Publication details: Mumbai Indian Drug Manufacture's Association - IDMA 2020Edition: Vol.57(01), JanDescription: 72-75pSubject(s): Online resources: In: Indian drugsSummary: Chromatography is the procedure for analysing a multicomponent mixture of trace, minor or major constituent by separaationinto its individual fractions.For the analytical determination of sildenafil in pharmaceutical dosages forms an expeditious & sensitive RP-HPLC method is described.The mobile phase composition for chromatographing sildenafil was acetonitrile: methanol: water(60:25:15, V/V/V) with a flow rate of 1mL/min using C18 column. The internal standard selected was racecadotril and its eluents were observed at 217nm. The retention time was 4.919 min for the drug. Between 5-200μg/mL the linearity of this method was observed. For analysis of drug in tablets, the depicted method was found to be appropriate. The results of the analysis was evaluated statistically. The method were found to be robust, accurate and economic with a major advantage of column longevity, as buffer was not used throughout the method. Hence the proposed method can be extended for routine analysis
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Status Barcode
Articles Abstract Database Articles Abstract Database School of Pharmacy Archieval Section Not for loan 2020996
Total holds: 0

Chromatography is the procedure for analysing a multicomponent mixture of trace, minor or major constituent by separaationinto its individual fractions.For the analytical determination of sildenafil in pharmaceutical dosages forms an expeditious & sensitive RP-HPLC method is described.The mobile phase composition for chromatographing sildenafil was acetonitrile: methanol: water(60:25:15, V/V/V) with a flow rate of 1mL/min using C18 column. The internal standard selected was racecadotril and its eluents were observed at 217nm. The retention time was 4.919 min for the drug. Between 5-200μg/mL the linearity of this method was observed. For analysis of drug in tablets, the depicted method was found to be appropriate. The results of the analysis was evaluated statistically. The method were found to be robust, accurate and economic with a major advantage of column longevity, as buffer was not used throughout the method. Hence the proposed method can be extended for routine analysis

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image
Share
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.