Local cover image
Local cover image
Image from Google Jackets

Development and Validation of Spectroscopic Simultaneous Equation Method for Simultaneous Estimation of Itopride Hydrochloride and Omeprazole in Synthetic Mixture

By: Contributor(s): Publication details: Raipur Asian Pharma Press 2019Edition: Vol.9(4), Oct-DecDescription: 238-242pSubject(s): Online resources: In: Asian journal of pharmaceutical researchSummary: A Simple, rapid, accurate, precise spectrophotometric method was developed and validated for simultaneous estimation of Itopride Hydrochloride and Omeprazole in synthetic mixture. The method is based on the simultaneous equation method. Itopride Hydrochloride has absorbance maxima at 258 nm and Omeprazole has absorbance maxima at 300 nm in methanol. Both drugs obey Beer’s law in the concentration range of 10-50 µg/ml (R2= 0.9994) for Itopride Hydrochloride and 2.5-12.5µg/ml (R2=0.9992) for Omeprazole. Limit of detection is 0.105 and 0.052 µg/ml and Limit of quantification is 0.320 and 0.160 µg/ml for Itopride Hydrochloride and Omeprazole, respectively. Percentage recovery for assay was found to be 99.68 % and 100.06 % for Itopride Hydrochloride and Omeprazole, respectively. The accuracy and reproducibility of the praposed method was statistically validated by recovery studies. The method was validated according to the ICH guidelines.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Status Barcode
Articles Abstract Database Articles Abstract Database School of Pharmacy Archieval Section Not for loan 2020-2021165
Total holds: 0

A Simple, rapid, accurate, precise spectrophotometric method was developed and validated for simultaneous estimation of Itopride Hydrochloride and Omeprazole in synthetic mixture. The method is based on the simultaneous equation method. Itopride Hydrochloride has absorbance maxima at 258 nm and Omeprazole has absorbance maxima at 300 nm in methanol. Both drugs obey Beer’s law in the concentration range of 10-50 µg/ml (R2= 0.9994) for Itopride Hydrochloride and 2.5-12.5µg/ml (R2=0.9992) for Omeprazole. Limit of detection is 0.105 and 0.052 µg/ml and Limit of quantification is 0.320 and 0.160 µg/ml for Itopride Hydrochloride and Omeprazole, respectively. Percentage recovery for assay was found to be 99.68 % and 100.06 % for Itopride Hydrochloride and Omeprazole, respectively. The accuracy and reproducibility of the praposed method was statistically validated by recovery studies. The method was validated according to the ICH guidelines.

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image
Share
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.