Local cover image
Local cover image
Image from Google Jackets

Power quality enhancement of grid connected wind farm using dynamic voltage restorer in Ethiopia

By: Contributor(s): Publication details: Hyderabad IUP Publications 2022Edition: Vol.15(3), JulyDescription: 7-23pSubject(s): In: IUP journal of electrical and electronics engineeringSummary: Rising sensitivity of the loads with respect to power quality has been a consideration for power systems and power quality enhancement systems. The fluctuation of voltage outside the normal working range due to faults may lead to undue interruption of wind turbines. The paper presents 1.5 MW grid connceted adama I wind farm in Ethiopia with the objective to capture the optimal power form the wind and ensure voltage source for sensitive load. It deals with effective voltage sag mitigation and harmonic distoration effectively and met IEEE 519-1992 standard under all phase-to-ground fault compensation using dynamic voltage restorer (DVR) to regulate the terminal voltage of the wind farm and safe operation of sensitive load.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Status Barcode
Articles Abstract Database Articles Abstract Database School of Engineering & Technology Archieval Section Not for loan 2022-2260
Total holds: 0

Rising sensitivity of the loads with respect to power quality has been a consideration for power systems and power quality enhancement systems. The fluctuation of voltage outside the normal working range due to faults may lead to undue interruption of wind turbines. The paper presents 1.5 MW grid connceted adama I wind farm in Ethiopia with the objective to capture the optimal power form the wind and ensure voltage source for sensitive load. It deals with effective voltage sag mitigation and harmonic distoration effectively and met IEEE 519-1992 standard under all phase-to-ground fault compensation using dynamic voltage restorer (DVR) to regulate the terminal voltage of the wind farm and safe operation of sensitive load.

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image
Share
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.