Performance analysis of three-phase grid-connected solar photovoltaic system with dynamic grid support system.

By: Contributor(s): Publication details: Telangana IUP Publications 2022Edition: Vol15(4), OctDescription: 55-69pSubject(s): Online resources: In: IUP journal of electrical and electronics engineeringSummary: Global energy needs are growing continuously, and there is now more focus on renewable energy sources. Solar Photovoltaic (PV) and wind have the major contribution among utility-level renewable energy sources. In India, till now gridconnected solar PV systems do not follow any specialized controls for grid support during disturbance and they isolate the solar PV system immediately with the help of anti-islanding technique. The paper presents a synchronous reference frame-based current control technique for solar PV inverters with low voltage ride-through control. A detailed performance analysis of grid-connected solar PV systems with and without low voltage ride-through control for various types of grid faults has been carried out. Various parameters like active and reactive power injection, circuit breaker opening time, dc-link voltage magnitude and voltage magnitude at the Point of Common Coupling (PCC) are recorded for symmetrical and unsymmetrical faults.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Status Barcode
Articles Abstract Database Articles Abstract Database School of Engineering & Technology Archieval Section Not for loan 2023-0630
Total holds: 0

Global energy needs are growing continuously, and there is now more focus on renewable energy sources. Solar Photovoltaic (PV) and wind have the major contribution among utility-level renewable energy sources. In India, till now gridconnected solar PV systems do not follow any specialized controls for grid support during disturbance and they isolate the solar PV system immediately with the help of anti-islanding technique. The paper presents a synchronous reference frame-based current control technique for solar PV inverters with low voltage ride-through control. A detailed performance analysis of grid-connected solar PV systems with and without low voltage ride-through control for various types of grid faults has been carried out. Various parameters like active and reactive power injection, circuit breaker opening time, dc-link voltage magnitude and voltage magnitude at the Point of Common Coupling (PCC) are recorded for symmetrical and unsymmetrical faults.

There are no comments on this title.

to post a comment.

Click on an image to view it in the image viewer

Local cover image
Share
Unique Visitors hit counter Total Page Views free counter
Implemented and Maintained by AIKTC-KRRC (Central Library).
For any Suggestions/Query Contact to library or Email: librarian@aiktc.ac.in | Ph:+91 22 27481247
Website/OPAC best viewed in Mozilla Browser in 1366X768 Resolution.